Installation guide

D000024-000 Rev. A A-1
Appendix A
SilverStorm 9000
Product Specifications
A.1
Physical Specifications
All products within the 9024 and 9000 Multi-protocol Fabric Director series are
designed to be installed in industry-standard 19-inch four-post server racks.
Racks should conform to conventional standards. Use the American National
Standards Institute (ANSI)/Electronic Industries Association (EIA) standard
ANSI/EIA-310-D-92 and International Electrotechnical Commission (IEC) 297.
These racks are commercially available in various depths. It is recommended to
use rack with minimum of 36" depth to facilitate cable installation and routing. Other
physical attributes are shown in the table below.
NOTE: The 9000 series MPFD products should not be installed in two-post
telecommunication racks.
A.2
Environmental Specifications
Operating temperature:
5° - 45°C at sea level, altitude derating 1°C per 300m to 2,400m
Non-operating temperature:
-35°C to 65°C
Relative humidity (non-condensing):
Operating 5% - 85%; Non-operating 5% - 90%
Table A-1. 9000 Physical Attributes
Model # 9024 9240 9120 9080 9040 9020
Height (rack
units/inches)
1U/1.75" 14U/24.5" 7U/12.25" 7U/12.25" 4U/7" 2U/3.5"
Depth (without
cables)
25 3/4" (654mm) 21"
(533mm)
Width 17.32" (440mm)
Max weight
(lb./kg.)
20/9 175/80 100/45 90/41 60/27 32/15