Installation guide
2 – Installation
D000024-000 Rev. A 2-11
Q
6. Using two screws, install the lower mounting bracket to the rail assembly and
chassis as shown in Figure 2-8.
Figure 2-8. Install the Lower Mounting Bracket and Heyclip
7. Install the heyclip to the rail assembly.
8. If applicable, reinstall the chassis fascia(s).
9. Tighten all screws.
2.3.7
Installing the Switch Fascia
To install the switch fascia(s):
1. On the switch fan side, insert the notches on the top of the fascia into the two
slots on the chassis frame. Snap the bottom of the fascia in place.
2.3.7.1
Installing the Modules (9020, 9040, 9080, 9120 and 9240)
NOTE: The purchased configuration for the SilverStorm 9000 is shipped fully
populated. Follow these steps when it becomes necessary to install or
replace spine modules and leaf modules.
1. Remove the necessary management modules/blanks, spine modules/blanks ,
leaf modules, virtual I/O cards (VICs) and blanks. For detailed instructions,
please refer to the section “Removing a Module or Blank” on page 2-12.
NOTE: If the user is only adding additional modules, remove only the blank(s)
for the slot(s) to be populated. These will not be replaced.
Install the lower rear
mounting bracket to the rail
assembly and chassis
Install the
heyclip here