Installation guide

2 – Installation
Installation Tasks
2-28 D000024-001 Rev. B
S
The fan speed has fallen below the minimum allowed RPM for a fan.
Power Supply LEDs (9020, 9040, 9080, 9120 and 9240)
Each power supply has two LEDs: DC OK and AC OK. Following are the status
definitions for each.
DC OK
Green indicates that DC power is normal.
Off indicates a DC power failure or no DC power is present.
AC OK
Green indicates that AC power is normal.
Off indicates a AC power failure or no AC power is present.
Module LEDs (9020, 9040, 9080, 9120 and 9240)
Leaf Module/FVIC/EVIC IB Port LEDs
Each module IB port has a Blue IB link status LED that provide the following
indications:
On - the logical link is up (port is in the Active state).
Off - the physical link is down (port is in the Down state).
Module Status LED
The status LED indicates one of the following conditions:
Steady Green - the module is operating normally.
•Blinking Green - LED test state.
Off - module is in the removable state.
Module Attention LED
The Attention LED indicates one of the following conditions:
Off - the system functioning normally.
Steady Amber - the system requires some attention, which could indicate one
of the following conditions:
The switch temperature is at a warning level on the module.
The switch silicon temperature is at a warning level (approximately 90 degrees
C).
DC voltages on the board are slightly out of tolerance (12V Bulk, 5V, 3.3V,
1.8V, VBIO are all monitored).
The module can no longer function properly. The system will take the
appropriate actions to ensure that no damage is done to its components.