Installation guide

2 – Installation
Installation Tasks
2-26 D000024-001 Rev. B
S
NOTE:
If spaces are used in the portName syntax (e.g., Cable 5), it must bounded
by quotes (i.e., “Cable 5).
4. Reboot the chassis to activate the changes.
5. Following the reboot, bring up Chassis Viewer. The 12X ports will be displayed
as shown in Figure 2-17 where all three ports of the group (ports 16, 17 and
18) have LEDs on.
Figure 2-17 12X Ports Enabled
6. From the 9024 main page, click on the menu buttons Port Stats/IB Port Stats
to displays the IB Port Statistics screen. The 12X port (for combined ports 16
through 18) is displayed as shown in Figure 2-18:
Figure 2-18 12X Port Statistics
The first port of the group (port 16) is shown as active and Up, while the other
two ports in the group are displayed as down and Disabled.
NOTE:
If the user decides to move the 12X group to a different set of ports, a reboot
is required to establish the new 12X link.
SilverStorm 9000 Component LEDs
Chassis Status LED
The chassis status LED (one per hemisphere) is Green when the system is
functioning normally.
The chassis status LED is Amber when one of the following conditions exists:
The system ambient temperature exceeds 52 C but remains less than 60 C.
Any Fan Alarm is amber.
Any power supply AC OK LED is off.