Installation guide
2 – Installation
Installation Tasks
2-24 D000024-001 Rev. B
S
Starting at 0x80010000...
sysI
REGS
BOOT
Initializing HyperTransport bus
HyperTransport initialization completed
Found Intel Strata Flash 128 MBit (0x8918).
Mounted raw file system on device /image1. (size=6291456 bytes)
Mounted raw file system on device /image2. (size=6291456 bytes)
Mounted raw file system on device /dump0. (size=1048576 bytes)
Mounted flash file system on device /rfa1. (size=2097152 bytes)
Network configuration requested.
cliEnabled=1
sbe0 speed=100 fullDuplex=0 flowControl=0
sbe1 speed=100 fullDuplex=1 flowControl=0
NOTE:
The command spineip changes the IP address for image1 and image2 on
each managed spine.
Enabling 12X Ports (9024 and 9080)
Users can enable 12X ports with the following CLI commands:
• ismChassisSet12x: Enables all external ports for 12x. This command has the
following syntax:
ismChassisSet12x <n>
The option n can be either 2 (12x mode is ENABLED 12X ONLY), 1 (12x mode
is ENABLED AUTO 1X/4X/12X) or 0 (disable).
For example:
ismChassisSet12x 2
enables 12X on all external ports.
NOTE:
Enabling all external ports for 12X may cause some latency issues. It is
recommended that users enable 12X only for the specific ports they need.