Installation guide
2 – Installation
Installation Tasks
D000024-001 Rev. B 2-19
A
Bringing Up the System For the First Time
Start-up Procedures
1. Power up the switch.
2. From its flash image on the spine module, the switch begins its boot process.
NOTE:
If the spine module RS-232 port is connected to a terminal emulation
program, the user will be able to view the switch boot process. Be certain to
use a null-modem/crossover serial cable for the console port (for serial port
pinout information, refer to Appendix C). The settings for the terminal
emulation device should be:
• 8 data bits
• no parity bits
• 1 stop bit
• 57.6K baud
• Use VT100 emulation.
• Flow control = XON/XOFF
3. Verify the IP address with the command line interface (CLI) command
showChassisIpAddr command. The system returns the information similar
to the following:
Chassis IP Address: 192.168.100.9 Net mask: 255.255.240.0
Changing the Switch IP Address and Default Gateway via the CLI
The command line interface (CLI) can be accessed via Telnet, SSH, or through the
switch RS-232 serial ports.
1. Connect null-modem/crossover serial cables to the RS-232 ports of the switch.
If using a terminal emulation device, the settings should be:
• 8 data bits
• no parity bits
• 1 stop bit
• 57.6K baud
• Use VT100 emulation.
• Flow control = XON/XOFF