Installation guide

Booting from the external storage array
51
Installation and Configuration
Press Enter to return to the previous menu as shown in
Figure 28 on page 49.
Option 3 (Edit Database) allows the appropriate WWN of the
array port, and the LUN address, to be specified for boot.
Figure 31 Example array port WWN and LUN values
Type 3 and press Enter.
Select 0 to select the first WWN database entry.
Press Enter.
The utility prompts for Entry 0 Port WWN.
15. Type the full WWN of the array port being used for boot and
press Enter.
The utility prompts for Node WWN.
16. Enter the same WWN used above and press Enter.
The utility prompts for the hexadecimal LUN address to be used
for boot;
17. Type the appropriate hexadecimal LUN value to be used for boot
and press Enter. Figure 31 shows example array-port WWN and
LUN values.
Note: This utility does not explicitly check the values entered for validity,
care must be taken to ensure that the proper array port WWN and LUN
addresses have been entered.
The utility will prompt for another WWN database entry to
modify,
18. Press Enter to return to the menu as shown in Figure 28 on
page 49.
19. Save the configuration changes by typing 11 (Write) and press
Enter.