Installation guide
44
EMC Host Connectivity with QLogic Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
Figure 22 Fibre Channel Card Efi utility
The QLogic adapter(s) installed in the server will be listed (as shown
in Figure 22). Note the "firmware" version listed in the utility. If the
firmware is listed as a specific version (not a series of zeroes), and
"AUX" is not listed next to the firmware field at the top of the report
then the EFI driver and firmware have been loaded on the adapter(s);
proceed to the section immediately following Figure 25 on page 47.
If the firmware is listed as a series of zeros, and "AUX" is listed next to
the firmware field at the top of the report (as shown in Figure 22), this
indicates the EFI boot code has not yet been installed on the
adapter(s). Proceed as follows:
To install the EFI boot code driver and non-volatile RAM settings on the
adapter(s):
The EFI boot code driver must be loaded onto the adapter(s) in order
to be used by the EFI BIOS.
1. Type update.nsh <qxxxxxxx.bin>, inserting the name of the EFI
boot driver package (bin file). The update procedure with run and
appear similar to the output shown in Figure 22.
2. Press Enter.