Installation guide

34
EMC Host Connectivity with QLogic Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
For example, Figure 13 shows that LUN 17 is masked to the
adapter. The LUN is available and is presented as "Supported" by
the BIOS.
Figure 13 Example of LUN 17 allocated to adapter
If no numbered entries appear in the above figure, verify the
following:
For VNX series or CLARiiON systems, verify the single I/O
path points to the SP that owns the boot LUN.
Verify array LUN masking settings are configured so this
adapter has visibility to the appropriate LUN. Refer to array
software documentation for details.
10. Select a supported LUN to use as the boot LUN (shown as LUN
17 in Figure 13) and press
Enter.
The Selectable Boot Settings dialog is displayed (Figure 14 on
page 35) with the updated array port and LUN number as the
boot device.