Installation guide

Booting from the external storage array
33
Installation and Configuration
Figure 12 Select Fibre Channel Device window
If no entries appear at any target IDs, verify the following:
If multiple adapters are present, verify the adapter select in the
BIOS Utility is the same that currently provides the I/O path
to the storage (at this point, only one I/O path should be
configured to the boot LUN).
For VNX series or CLARiiON systems, verify that the single
I/O path points to the SP which owns the boot LUN.
For FC-SW environments, verify fabric zoning parameters, so
a single I/O path exists to the boot LUN. Refer to array
software documentation for details.
Check physical FC connectivity between the adapter and
array (direct attach environment) or switch (FC-SW
environment).
9. Select the array port to be used for boot, and press Enter.
If LUNs are allocated to the adapter (using LUN Masking
schemes, such as Access Logix
or Volume Logix), they will be
presented at their LUN number.