Installation guide
Booting from the external storage array
33
Installation and Configuration
Figure 12 Select Fibre Channel Device window
If no entries appear at any target IDs, verify the following:
• If multiple adapters are present, verify the adapter select in the
BIOS Utility is the same that currently provides the I/O path
to the storage (at this point, only one I/O path should be
configured to the boot LUN).
• For VNX series or CLARiiON systems, verify that the single
I/O path points to the SP which owns the boot LUN.
• For FC-SW environments, verify fabric zoning parameters, so
a single I/O path exists to the boot LUN. Refer to array
software documentation for details.
• Check physical FC connectivity between the adapter and
array (direct attach environment) or switch (FC-SW
environment).
9. Select the array port to be used for boot, and press Enter.
If LUNs are allocated to the adapter (using LUN Masking
schemes, such as Access Logix
™
or Volume Logix), they will be
presented at their LUN number.