10 – Performing Diagnostics
Preparing for Normal HBA Operations
10-12 FS0054603-00 C
Q
❑ R/W buffer not supported
❑ Write buffer failed
■ Link Failure. Number of link failures
■ Sync Loss. Number of sync loss errors
■ Signal Loss. Number of signal loss errors
■ Invalid CRC. Number of invalid CRCs
If the value in the Data Miscompare column is nonzero, you can view the
miscompare information by double-clicking any column. The Diagnostic Details
dialog box displays (see figure 10-5).
Figure 10-5. Data Miscompare Results
Do the following as appropriate:
■ Click Next to view the details of the next miscompare.
■ Click Previous to view the details of the previous miscompare.
■ Click Close to return to the Diagnostics tabbed page.
10.5
Preparing for Normal HBA Operations
When loopback testing is complete, do the following to resume normal HBA
operations:
1. Do the following to remove the loopback connector:
a. Remove the loopback connector from the HBA connector.
b. Reconnect the cable that you disconnected in section 10.1.2.2.
2. Modify the HBA settings Connection Options back to its previous setting (see
section 10.1.2.1).