User`s guide
10 – Performing Diagnostics
Preparing for Diagnostic Testing
FS0054603-00 C 10-3
Q
10.1.2
Preparing for the Loopback Test
Perform the following steps before running the loopback test:
1. Modify the HBA port settings Connection Options setting (see
section 10.1.2.1).
2. Attach a loopback connector to the Fibre Channel connector on the HBA port
(see section 10.1.2.2).
Skip this step under the following conditions (an echo test will be run instead):
❑ You have a QLA23xx HBA that is connected to the fabric through a
point-to-point connection (F-port).
❑ The HBA is connected to a switch.
❑ Your operating system has one of the driver versions listed in table 10-1.
3. If the HBA port is connected to the fabric through a point-to-point connection
(F-port) and is connected to a switch, make sure the Connection Options
setting is 1—Point-to-Point Only. See section 11.1.1 for information about
viewing and modifying the setting.
Table 10-1. Driver Versions that Do Not Require a Loopback Connector
Operating System Driver Version
Windows 2000/Windows Server 2003 with SCSI miniport driver 8.2.3.11 and above
Windows Server 2003 with STORport miniport driver 8.2.3.16 and above
Red Hat/SuSE Linux 6.06.00 and above
Solaris SPARC 4.12 and above
Novell NetWare 6.80 and above