Installation guide

16
FIGURE 3 ZFS STORAGE APPLIANCE LUN ASSIGNMENT DISPLAY
2. Reboot the servers to discover the assigned LUNs.
On the SPARC Enterprise M5000 Server the following command is an intermediate check to ensure that the
hardware is seeing the LUNs in a pre-boot environment. The following information is the LUN portion
obtained from the SPARC Enterprise M5000 Server NVRAM display.
SPARC Enterprise M5000 Server, using Domain console
Copyright (c) 1998, 2010, Oracle and/or its affiliates. All rights
reserved.
Copyright (c) 2010, Oracle and/or its affiliates and Fujitsu Limited. All
rights reserved.
OpenBoot 4.24.15, 65536 MB memory installed, Serial #70949847.
Ethernet address 0:14:4f:3a:9b:d7, Host ID: 843a9bd7.
Aborting auto-boot sequence.
{0} ok show-devs
/pci@13,700000
:
:
:
/packages
/pci@12,600000/SUNW,qlc@0,3
/pci@12,600000/SUNW,qlc@0,2
/pci@12,600000/ethernet@0,1
/pci@12,600000/ethernet@0
/pci@12,600000/SUNW,qlc@0,3/fp@0,0
/pci@12,600000/SUNW,qlc@0,3/fp@0,0/disk
/pci@12,600000/SUNW,qlc@0,2/fp@0,0
/pci@12,600000/SUNW,qlc@0,2/fp@0,0/disk
:
:
:
/packages/SUNW,probe-error-handler
{0} ok
3. After booting Oracle Solaris on both systems, verify that the server operating system and the management
application can discover the assigned LUNs. Verify the LUNs are present with the FC info HBA-port