User`s guide
Table Of Contents
- Table of Contents
- Section1 Introduction
- Section2 Using SANbox Manager
- 2.1 Installing SANbox Manager
- 2.1.1 SANsurfer Management Suite Disk - Windows Installation
- 2.1.2 SANsurfer Management Suite Disk - Linux Installation
- 2.1.3 SANsurfer Management Suite Disk - Solaris Installation
- 2.1.4 SANbox2 Installation Disk - Windows Installation
- 2.1.5 SANbox2 Installation Disk - Linux Installation
- 2.1.6 SANbox2 Installation Disk - Solaris Installation
- 2.2 Starting SANbox Manager
- 2.3 Exiting SANbox Manager
- 2.4 Uninstalling SANbox Manager
- 2.5 Changing Default File Password
- 2.6 Setting Preferences
- 2.7 Using Online Help
- 2.8 Viewing Software Version and Copyright Information
- 2.9 SANbox Manager User Interface
- 2.10 Using the Topology Display
- 2.11 Using the Faceplate Display
- 2.1 Installing SANbox Manager
- Section3 Managing Fabrics
- 3.1 Security
- 3.2 Managing the Fabric Database
- 3.3 Replacing a Failed Switch
- 3.4 Displaying Fabric Information
- 3.5 Zoning a Fabric
- Section4 Managing Switches
- 4.1 Displaying Switch Information
- 4.2 Managing Alarms
- 4.3 Exporting Name Server Information to a File
- 4.4 Paging a Switch
- 4.5 Setting the Date and Time
- 4.6 Setting Temperature Thresholds
- 4.7 Resetting a Switch
- 4.8 Configuring a Switch
- 4.9 Archiving a Switch
- 4.10 Restoring a Switch
- 4.11 Managing Firmware
- 4.12 Restoring the Factory Default Configuration
- Section5 Managing Ports
- AppendixA Command Line Interface
- A.1 Logging On to a Switch
- A.2 Command Syntax
- A.3 Commands
- Admin Command
- Alias Command
- Config Command
- Date Command
- Fallback Command
- Help Command
- History Command
- Image Command
- Lip Command
- Passwd Command
- Ps Command
- Quit Command
- Reset Command
- Set Command
- Set Config Command
- Set Log Command
- Set Port Command
- Set Setup Command
- Show Command
- Show Config Command
- Show Log Command
- Show Perf Command
- Show Setup Command
- Shutdown Command
- Test Command
- Uptime Command
- User Command
- Whoami Command
- Zone Command
- Zoneset Command
- Zoning Command
- AppendixB Graphing Port Performance
- AppendixC Messages
- C.1 Fabrics File—Open, Save
- C.2 Add a Fabric
- C.3 Network Properties Dialog
- C.4 Switch Properties Dialog
- C.5 Port Properties Dialog
- C.6 Faceplate Display
- C.7 Firmware Fallback Dialog
- C.8 Load Firmware Dialog
- C.9 Port Loopback Test Dialog
- C.10 Extended Credits Dialog
- C.11 Zoning Dialog
- C.12 Restore Configuration Dialog
- C.13 Save Fabric View
- C.14 Trap Configuration Dialog
- Glossary
- Index

A – Command Line Interface
Admin Command
A-4 59022-05 A
Admin Command
Opens and closes an Admin session. The Admin session provides commands
that change the fabric and switch configurations. Only one Admin session can be
open on the switch at any time. An inactive Admin session will time out after a
period of time which can be changed using the Set Setup System command.
Refer to the Set Setup Command on page A-37.
Authority Admin
Syntax admin
start
end
cancel
Keywords start
Opens the admin session.
end
Closes the admin session. The Logout, Shutdown, and Reset Switch commands
will also end an admin session.
cancel
Terminates an Admin session opened by another user. Use this keyword with care
because it terminates the Admin session without warning the other user and
without saving pending changes.
Notes Closing a Telnet window during an admin session does not release the session. In
this case, you must either wait for the admin session to time out, or use the Admin
Cancel command.
Examples The following example shows how to open and close an Admin session:
SANbox2 #> admin start
SANbox2 (admin) #>
.
.
.
SANbox2 (admin) #> admin end