User`s guide
3 – Alarm Messages
Alarm Messages
59060-00 01 PRELIMINARY 3-13
0
[A1004.0020] [Eport] [R_A_TOV mismatch indicated on ELP]
Meaning: An E_Port isolated because the R_A_TOV timeout values on the
two switches do not match.
Action: Modify R_A_TOV so that it is the same on both switches. The
recommended value is 10 seconds.
[A1004.0021] [Eport] [E_D_TOV mismatch indicated on ELP]
Meaning: An E_Port isolated because the E_D_TOV timeout values on the
two switches do not match.
Action: Modify E_D_TOV so that it is the same on both switches. The
recommended value is 2 seconds.
[A1004.0022] [Eport] [EFP indicates Domain id <domain> assigned to different switches]
Meaning: An E_Port isolated because two switches in the fabric have the
same domain ID.
Action: Modify the switches so that all domain IDs are unique.
[A1004.0023] [Eport] [Attempting to connect to switch with incompatible TOV]
Meaning: An E_Port isolated because the values for R_A_TOV or E_D_TOV
are not the same on both switches.
Action: Modify the switches so that the time out values are the same.
[A1004.0024] [Eport] [Attempting to connect to switch that is in non-interoperability mode]
Meaning: An attempt was made to connect to a switch with a different value
for FC-SW-2 compliance.
Action: Modify the FC-SW-2 compliance values so that they are the same
on both switches.
[A1004.0025] [Eport] [ESC RJT received]
Meaning: An attempt has been made to connect to another switch that
rejected the ESC (Exchange Switch Capabilities) request for a
reason other than command not supported.
Action: Install compatible firmware.
[A1004.0026] [Eport] [Configured domain id <domain id number> not available]
Meaning: An attempt was made to connect a switch to a fabric with a
conflicting domain ID and the domain ID could not be reassigned.
Action: Change the domain ID so that it is unique in the fabric or disable
the domain ID lock so that the domain ID can be automatically
reassigned.