User`s guide
3 – Alarm Messages
Alarm Messages
3-6 PRELIMINARY 59060-00 01
0
[A1003.000C] [Zoning] [Fabric Busy, Failing lock request from domain <domain #>]
Meaning: An attempt was made to activate or deactivate a zone set while
another activation or deactivation was is progress.
Action: Retry later.
[A1003.000D] [Zoning] [Failed to lock fabric, lock already held by switch with domain
<domain>]
Meaning: Another switch in the fabric already has locked.
Action: The lock must be released on the other switch.
[A1003.000E] [Zoning] [Couldn't acquire lock from domain <domain>]
Meaning: Fabric may be changing, couldn't acquire lock.
Action: Wait for Fabric to stabilize, try again.
A1003.000F] [Zoning] [No memory for command LOCK completion]
Meaning: A zone set activation or deactivation failed because of limited
resources.
Action: Retry later.
[A1003.0015] [Zoning] [Zoneset Activation received from switch with domain <domain>
failed, Unknown zoneset <zoneset>]
Meaning: A zone set activation received from the named switch failed
because the zone set was not in the zoning database.
Action: Examine the named switch to verify that the zoning database is
correct.
[A1003.0016] [Zoning] [Dropping lock held by domain <domain>, Merge requests
outstanding]
Meaning: Zone merge could not complete in the acceptable time.
Action: Check the status of the switch given domain ID.
[A1003.001B] [Zoning] [Failing SFC, total zoneset limit would be exceeded]
Meaning: The maximum number of zone sets has been exceeded on the
switch as a result of a zone merge.
Action: Reduce the number of zone sets on the remote switch.
[A1003.001C] [Zoning] [Failing SFC, total member limit would be exceeded]
Meaning: The maximum number of zone members has been exceeded on
the switch due to a zone merge.
Action: Reduce the number of zone members on the remote switch.