User`s guide
3 – Alarm Messages
Alarm Messages
59060-00 01 PRELIMINARY 3-3
0
A1000.000C] [SM] [The switch will be shutdown several seconds]
Meaning: The switch is being reset as a result of a command from a user
interface.
Action: None
[A1000.000D] [SM] [The switch will NDCLA in several seconds]
Meaning: An nondisruptive code load and activation will occur as a result of a
Hotreset command from the user interface.
Action: None
[A1000.000F] [SM] [The switch is backing out of NDCLA]
Meaning: Cannot move forward with the nondisruptive code load and
activation. All applications and switch resources are backing out of
the procedure and returning to normal operation.
Action: Ensure that the fabric is stable and that no changes are being
made to switch configurations or connections and try again.
[A1000.0011] [SM] [The switch is being reset while in config edit mode]
Meaning: The switch was reset before pending changes to the switch
configuration were saved – all changes were lost.
Action: Save pending changes to the switch configuration before resetting
the switch.
[A1000.0012] [SM] [The switch is being reset while in zoning edit mode]
Meaning: The switch was reset before pending zoning changes were saved
– all changes were lost.
Action: Save pending zoning changes before resetting the switch.
[A1000.0013] [SM] [The switch is being reset]
Meaning: The switch is being reset.
Action: None
[A1000.0015] [SM] [The switch is being reset while in snmp setup mode]
Meaning: The switch was reset before pending changes to the SNMP
configuration were saved – all changes were lost.
Action: Save pending changes before resetting the switch.
[A1000.0016] [SM] [The switch is being reset while in system setup mode]
Meaning: The switch was reset before pending changes to the system setup
were saved – all changes were lost.
Action: Save pending changes before resetting the switch.