Installation guide

B – Command Line Interface
Show Config Command
59043-01 B B-59
Q
FANEnable False
LCFEnable False
MFSEnable False
MFS_TOV 640
MSEnable False
NoClose False
IOStreamGuard False
VIEnable False
CheckAlps False
The following is an example of the Show Config Switch command:
SANbox2 #> show config switch
Configuration Name: default
-------------------
Switch Configuration Information
--------------------------------
AdminState Online
BroadcastEnabled True
InbandEnabled True
DomainID 100 (0x64)
DomainIDLock False
SymbolicName SANbox2 N_11.107
R_T_TOV 100
R_A_TOV 10000
E_D_TOV 2000
FS_TOV 5000
DS_TOV 5000
PrincipalPriority 254
ConfigDescription QLogic SANbox2 FC Switch
ConfigLastSavedBy guest@IB-session10
ConfigLastSavedOn day month date time year
The following is an example of the Show Config Threshold command:
SANbox2 #> show config threshold
Configuration Name: default
------------
Threshold Configuration Information
-----------------------------------
ThresholdMonitoringEnabled True
CRCErrorsMonitoringEnabled True