B – Command Line Interface
Set Config Command
59043-01 B B-33
Q
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Rising Trigger The event count above which a rising
threshold alarm is logged. The switch will
not generate another rising threshold
alarm for that event until the count
descends below the falling threshold and
again exceeds the rising threshold.
Falling Trigger The event count below which a falling
threshold alarm is logged. The switch will
not generate another falling threshold
alarm for that event until the count
exceeds the rising threshold and
descends again below the falling
threshold.
Sample Window The period of time in seconds in which to
count events.
Table B-10. Set Config Zoning Parameters
Parameter Description
AutoSave Enables (True) or disables (False) the
saving of changes to active zone set in the
switch’s permanent memory. Changes are
always saved in the switch’s temporary
memory.
Default Enables (All) or disables (None)
communication among the switch’s ports/
devices and the fabric in the absence of an
active zone set.
Table B-9. Set Config Threshold Parameters (Continued)
Parameter Description