D Simplify SANbox2-64 Fibre Channel Switch Installation Guide 59043-01 B Page i
Q SANbox2-64 Fibre Channel Switch Installation Guide Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only.
Table of Contents Section 1 Introduction 1.1 1.2 1.3 1.4 1.5 1.6 1.6.1 1.6.2 1.6.4 1.6.5 1.6.6 1.7 1.8 1.9 1.10 1.11 1.12 1.12.1 1.12.2 1.12.3 Intended Audience ............................................................................................. 1-1 Related Materials ............................................................................................... 1-2 Safety Notices ....................................................................................................
SANbox2-64 Fibre Channel Switch Installation Guide Q 2.3 2.3.1 2.3.2 2.3.3 2.3.3.1 2.3.3.2 2.3.3.3 2.4 2.5 2.6 2.7 2.8 Fibre Channel Ports ........................................................................................... 2-7 Small Form-Factor Pluggable (SFP) Transceivers .................................... 2-8 Port Status LED ......................................................................................... 2-8 Port Modes .................................................................
Q SANbox2-64 Fibre Channel Switch Installation Guide 4.2.4 4.2.4.1 4.2.4.2 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 4.2.10 4.2.11 4.2.12 4.2.13 4.2.14 4.3 4.3.1 4.3.2 4.3.3 4.4 Connect the Management Workstation to the Switch................................ 4-7 Ethernet Connection ......................................................................... 4-8 Serial Connection ............................................................................. 4-8 Installing SANbox Manager ..................................
SANbox2-64 Fibre Channel Switch Installation Guide 5.3.4 5.3.5 5.3.6 5.3.7 5.3.8 Q Maintenance – Reset Password File ....................................................... 5-14 Maintenance – Copy Log Files ................................................................ 5-14 Maintenance – Remove Switch Config.................................................... 5-14 Maintenance – Remake Filesystem ........................................................ 5-14 Maintenance – Reset Switch ...................
Q SANbox2-64 Fibre Channel Switch Installation Guide Date Command .........................................................................................B-9 Fallback Command..................................................................................B-10 Hotswap Command ................................................................................. B-11 Help Command........................................................................................B-13 History Command.........................
Q SANbox2-64 Fibre Channel Switch Installation Guide 2-5 2-6 2-7 2-8 2-9 2-10 3-1 3-2 4-1 4-2 4-3 5-1 5-2 5-3 6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8 Fibre Channel Ports ....................................................................................................... 2-7 SFP Transceiver ............................................................................................................ 2-8 Ethernet Port ................................................................................................
Section 1 Introduction This manual describes the features and installation of the SANbox2-64 Fibre Channel switch, firmware version 1.5.1. This manual is organized as follows: Section 1 describes the intended audience, related materials, safety notices, communications statements, laser safety information, electrostatic discharge sensitivity precautions, accessible parts, and technical support. Section 2 is an overview of the switch. It describes indicator LEDs and all user controls and connections.
Q 1 – Introduction Related Materials 1.2 Related Materials The following manuals and materials are referenced in the text and/or provide additional information. SANbox2-64 Switch Management User’s Guide, Publication Number 59048-01. Fibre Channel-Arbitrated Loop (FC-AL-2) Rev. 6.8. Fibre Channel-Private Loop SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fibre Channel-10-bit Interface Rev. 2.3.
Q 1 – Introduction Safety Notices 1.3 Safety Notices A Warning notice indicates the presence of a hazard that has the potential of causing personal injury. 4-3, 4-5, 6-2, 6-8, 6-12, 6-15, 6-16, 6-18 A Caution notice indicates the presence of a hazard that has the potential of causing damage to the equipment. 4-3, 5-14, 6-2, 6-4, 6-8, 6-11, 6-16, 6-18 1.4 Sicherheitshinweise Ein Warnhinweis weist auf das Vorhandensein einer Gefahr hin, die möglicherweise Verletzungen zur Folge hat.
1 – Introduction Communications Statements Q 1.6 Communications Statements The following statements apply to this product. The statements for other products intended for use with this product appear in their accompanying manuals. 1.6.1 Federal Communications Commission (FCC) Class A Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Q 1 – Introduction Communications Statements 1.6.3 Avis de conformité aux normes du ministère des Communications du Canada Cet équipement ne dépasse pas les limites de Classe A d'émission de bruits radioélectriques por les appareils numériques, telles que prescrites par le Réglement sur le brouillage radioélectrique établi par le ministère des Communications du Canada.
1 – Introduction Communications Statements Q 1.6.5 VCCI Class A Statement This is a Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. 1.6.6 BSMI Class A Statement Warning: This is a Class A product.
Q 1 – Introduction Laser Safety Information 1.7 Laser Safety Information This product may use Class 1 laser optical transceivers to communicate over the fiber optic conductors. The U.S. Department of Health and Human Services (DHHS) does not consider Class 1 lasers to be hazardous. The International Electrotechnical Commission (IEC) 825 Laser Safety Standard requires labeling in English, German, Finnish, and French stating that the product uses Class 1 lasers.
Q 1 – Introduction Accessible Parts 1.9 Accessible Parts The Field Replaceable Units (FRUs) in the SANbox2-64 switch are: Small Form-Factor Pluggable (SFP) optical transceivers CPU module I/O blades Power supply modules Fans Refer to Section 6 Removal/Replacement for more information. 1.
Q 1 – Introduction Technical Support 1.12 Technical Support Customers should contact their authorized maintenance provider for technical support of their QLogic switch products. QLogic-direct customers may contact QLogic Technical Support; others will be redirected to their authorized maintenance provider. Visit the QLogic switch support Web site listed in Contact Information for the latest firmware and software updates. 1.12.
1 – Introduction Technical Support Q Notes 1-10 59043-01 B
Section 2 General Description This section describes the features and capabilities of the SANbox2-64 Fibre Channel switch. The following topics are described: Chassis hardware Chassis controls and LEDs Fibre channel ports Ethernet port Serial port Switch management Fabrics are managed with the SANbox Manager switch management application (version 1.05) and the Command Line Interface (CLI). Refer to Appendix B Command Line Interface for more information.
Q 2 – General Description Chassis Hardware 2.1 Chassis Hardware The SANbox2-64 switch is set of up to eight 8-port I/O blades. Each I/O blade is interconnected with all other I/O blades through the backplane which is supported by four cross-connect ASICs. A CPU module provides configuration, monitoring, data path management, and control functions. The base SANbox2-64 switch is configured as a 16-port switch. The 16-port switch is equipped with 2 I/O blades, 2 power supply modules, and a CPU module.
Q 2 – General Description Chassis Hardware There are 11 slots numbered #0–#10 as shown in Figure 2-2. Power supply modules occupy slots #0 and #10. The CPU module occupies slot #5. I/O blades occupy slots #1–#4 and #6–#9. The Fibre Channel ports on the I/O blades are numbered 0–63 from top to bottom according to slot number as shown in Figure 2-2. For example, the ports 0–7 are always associated with the I/O blade in slot #1; ports 8–15 are always associated with slot #2, and so on.
Q 2 – General Description Chassis Controls and LEDs 2.2 Chassis Controls and LEDs The Maintenance button on the CPU module, as shown in Figure 2-3, is the only chassis control. Power is applied to the switch logic circuitry when one or both power supply modules are connected to a 110 or 230 VAC power source. The chassis LEDs are located on the CPU module and provide status information about the condition of the switch.
Q 2 – General Description Chassis Controls and LEDs 2.2.1 Maintenance Button The Maintenance button is dual function control on the CPU module that resets the switch or places the switch in maintenance mode. Maintenance mode sets the IP address to 10.0.0.1 and provides access to the switch for maintenance purposes when flash memory or the resident configuration file is corrupted. Refer to ”Recovering a Switch” on page 5-12 for information about maintenance mode. 2.2.1.
Q 2 – General Description Chassis Controls and LEDs 2.2.2 Chassis LEDs The chassis LEDs shown in Figure 2-4 provide status information about switch operation. Input Power LED (Green) Heartbeat LED (Amber) Fan Fail LED (Amber) Over Temperature LED (Amber) Figure 2-4. Chassis LEDs 2.2.2.1 Input Power LED (Green) The Input Power LED indicates the voltage status at the switch logic circuitry. This LED illuminates when the switch logic circuitry is receiving the proper DC voltages. 2.2.2.
Q 2 – General Description Fibre Channel Ports 2.2.2.3 Fan Fail LED (Amber) The Fan Fail LED indicates operational status of all fans. This LED illuminates if the speed of any fan falls below the normal range. Removing a fan will not illuminate the Fan Fail LED. Refer to Section 5 Diagnostics/Troubleshooting for information about troubleshooting fan failure conditions. 2.2.2.4 Over Temperature LED (Amber) The Over Temperature LED provides status information about the air temperature inside the switch.
Q 2 – General Description Fibre Channel Ports 2.3.1 Small Form-Factor Pluggable (SFP) Transceivers An SFP transceiver, like the one shown in Figure 2-6, converts electrical signals to and from optical laser signals to transmit and receive data. SFP transceivers plug into the ports; duplex fiber optic cables plug into the transceivers which then connect to the devices.
Q 2 – General Description Fibre Channel Ports 2.3.3 Port Modes SANbox2-64 switches support the following port modes: Generic ports (GL_Port and G_Port) Fabric ports (FL_Port and F_Port) Translated loop ports (TL_Port) Expansion ports (E_Port) Switches come from the factory with all ports configured as GL_Ports. GL_Ports self-configure in the following ways: FL_Port when connected to a loop of public devices F_Port when connected to a single public device.
2 – General Description Fibre Channel Ports Q 2.3.3.2 Translated Loop Port A TL_Port supports a loop of up 124 private target devices with the ability to communicate with up to 63 “off-loop” public devices. Private loop Initiator devices are not supported on the TL_Port. The TL_Port acts as a proxy for the off-loop device translating private frames into and from public frames. The set of off-loop devices are maintained in the TL_Port’s translation entries list.
Q 2 – General Description Ethernet Port 2.4 Ethernet Port The Ethernet port is a RJ-45 connector located on the CPU module as shown in Figure 2-7. This port requires a 10/100BASE-T cable and provides a connection for a management workstation, such as a PC, a Solaris™ workstation, or a Linux® workstation, through which to manage the switch. You can manage the switch over an Ethernet connection using SANbox Manager, the Command Line Interface (CLI), or SNMP.
Q 2 – General Description Serial Port 2.5 Serial Port The SANbox2-64 switch is equipped with an RS-232 serial port for maintenance purposes. The serial port is located on the CPU module as shown in Figure 2-8. 6 1 9 5 Serial Port Figure 2-8. Serial Port The serial port connector requires a null-modem F/F DB9 cable. The pins on the switch RS-232 connector, shown in Figure 2-8, are identified in Table 2-1.
Q 2 – General Description Power Supply Modules 2.6 Power Supply Modules The power supply modules convert standard 110 or 230 VAC to DC voltages for the various switch circuits. Each power supply module has an AC power receptacle and two status LEDs as shown in Figure 2-9. Each power supply module is capable of providing all of the switch’s power needs. During normal operation, each power supply provides half of the demand.
Q 2 – General Description Fans 2.7 Fans The switch is equipped with three fans as shown in Figure 2-10. If one of the fans should fail, the other two fans are capable of providing the necessary cooling until the failed fan can be replaced. The fans are hot pluggable and interchangeable. Refer to ”Fans” on page 6-18 for information about removing and replacing the fans. Air flow can be back-to-front or front-to-back depending on the model. Fans Figure 2-10.
Q 2 – General Description Switch Management 2.8 Switch Management SANbox Manager is a workstation-based Java® application that provides a graphical user interface for fabric management. This application runs on a Windows®, Solaris, or Linux workstation. The management workstation connects to the switch through the switch’s Ethernet port. Refer to the SANbox2-64 Switch Management User’s Guide for information about the SANbox Manager application and its use.
2 – General Description Switch Management Q Notes 2-16 59043-01 B
Section 3 Planning Consider the following when planning a fabric: Devices Multiple chassis fabrics Performance Device access Fabric management Fabric security 3.1 Devices When planning a fabric, consider the number of devices, the types of device (public or private), and the anticipated demand. This will determine the number of ports that are needed and in turn the number of switches. Consider how many switches are needed and how to connect the devices.
Q 3 – Planning Devices 3.1.2 Redundancy and Latency When planning a fabric, consider how to create redundant paths and minimize latency. Initiators and targets experience the least amount of latency when connected to the same I/O blade. For example, connecting initiator and target “A” ports together on one I/O blade and initiator and target “B” ports on another I/O blade, as shown in Figure 3-1, creates redundant paths and minimizes latency. Initiators A B A B Targets Figure 3-1.
Q 3 – Planning Devices For a multiple switch fabrics in which initiators on one switch communicate with targets on another, the same principles apply as shown in Figure 3-2. The “A” port initiators and E_Ports are grouped together on one I/O blade with connections to the corresponding “A” port targets and E_Ports on the same I/O blade on the second switch. “B” port initiators, targets, and links are connected in a similar way. Initiators A A B B Targets Figure 3-2.
Q 3 – Planning Multiple Chassis Fabrics 3.2 Multiple Chassis Fabrics By connecting switches together you can expand the number of available ports for devices. Each switch in the fabric is identified by a unique domain ID, and the fabric will automatically resolve domain ID conflicts. Because the ports are selfconfiguring, you can connect SANbox2-64 and other FC-SW-2 compliant switches together in a wide variety of topologies. 3.2.
Q 3 – Planning Multiple Chassis Fabrics 3.2.2 Common Topologies The SANbox2-64 switch supports describes three commonly used fabric topologies: Cascade Mesh Multistage® A cascade topology describes a fabric in which the switches are connected in a linear fashion. If you connect the last switch back to the first switch, you create a cascade-with-a-loop topology. The loop reduces latency because any switch can route traffic in the shortest direction to any switch in the loop.
Q 3 – Planning Performance 3.3 Performance The SANbox2-64 switch supports class 2 and class 3 Fibre Channel service at transmission rates of 1 Gbps or 2 Gbps with a maximum frame size of 2148 bytes. A port can transmit or receive at 1 Gbps or 2 Gbps depending on the device to which it is connected. The port discovers the transmission speed prior to login when the connected device powers up. Related performance characteristics include the following: Distance Bandwidth Latency 3.3.
Q 3 – Planning Performance 3.3.2 Bandwidth Bandwidth is a measure of the volume of data that can be transmitted at a given transmission rate. A port can transmit or receive at 1 Gbps or 2 Gbps depending on the device to which it is connected. The switch supports all transmission rate combinations as shown in Table 3-1. Table 3-1.
Q 3 – Planning Device Access 3.4 Device Access Consider device access needs within the fabric. Access is controlled by the use of zones and zone sets. Some zoning strategies include the following: Separate devices that use different operating systems. Separate devices that have no need to communicate with other devices in the fabric or have classified data. Separate devices into department, administrative, or other functional group.
Q 3 – Planning Device Access 3.4.1 Soft Zone Soft zoning divides the fabric for purposes of controlling discovery. Members of the same soft zone automatically discover and communicate freely with all other members of the same zone. The soft zone boundary is not secure; traffic across soft zones can occur if addressed correctly. The following rules apply to soft zones: Soft zones that include members from multiple switches need not include the ports of the inter-switch links.
Q 3 – Planning Fabric Management 3.4.3 Virtual Private Fabric Hard Zones Virtual Private Fabric (VPF) zoning divides the fabric for purposes of controlling discovery and both inbound and outbound traffic. This type of zoning is useful for providing security and reserving paths between devices to guarantee bandwidth. VPF zoning is a type of hard zoning that is hardware enforced. Members can only transmit to and receive from members of the same VPF zone.
Q 3 – Planning Fabric Security 3.6 Fabric Security You manage fabric security on a switch basis through the creation of user accounts. Each account consists of an account name, a password, and an authority level. There are two authority levels: User and Admin. These authority levels apply to SANbox Manager and to the CLI. User authority permits only monitoring and display tasks. Admin authority permits all management tasks including user administration.
3 – Planning Fabric Security Q Notes 3-12 59043-01 B
Section 4 Installation This section describes how to install and configure the SANbox2-64 switch. It also describes how to load new firmware. 4.1 Site Requirements Consider the following items when installing a SANbox2-64 switch: Fabric management workstation Power requirements Environmental conditions 4.1.1 Fabric Management Workstation The requirements for fabric management workstations running SANbox Manager are described in Table 4-1: Table 4-1.
Q 4 – Installation Installing a Switch 4.1.3 Environmental Conditions Consider the factors that affect the climate in your facility such as equipment heat dissipation and ventilation. The switch requires the following operating conditions: Operating temperature range: 5° to 40° C (41°- 104°F) Relative humidity: 15% - 80%, non-condensing 4.2 Installing a Switch Unpack the switch and accessories.
Q 4 – Installation Installing a Switch Installing a SANbox2-64 switch involves the following steps: 1. Mount the switch. 2. Install SFP transceivers. 3. Connect the switch to the AC power source. 4. Connect the management workstation to the switch. 5. Install SANbox Manager. 6. Configure the switch. 7. Configure the ports. 8. Cable devices to the switch. 4.2.1 Mount the Switch 59043-01 B WARNING!! Two people are required to safely lift and install the SANbox2-64 switch into a rack.
Q 4 – Installation Installing a Switch The switch is designed to be mounted in a rack using the mounting brackets and the SANbox2-64 rail kit shown in Figure 4-2. To mount the switch in a rack, do the following. Rack mounting instructions can also be found in the SANbox2-64 Rack Mounting Guide packaged with the switch. 6 8 4 2 9 5 1 6 9 1 3 7 Figure 4-2. SANbox2-64 Rail Kit 4-4 1. You can install the switch in a rack “fans first” or “faceplate first”.
Q 4 – Installation Installing a Switch 4.2.2 Install SFP Transceivers The switch will support a variety of interconnection media. Refer to ”SFP Transceivers” on page 6-1 for information about removing and installing SFP transceivers. 4.2.3 Connect the Switch to AC Power WARNING!! This product is supplied with a 3-wire power cable and plug for the user’s safety. Use this power cable in conjunction with a properly grounded outlet to avoid electrical shock.
Q 4 – Installation Installing a Switch WARNUNG!! Dieses Produkt wird mit einem 3-adrigen Netzkabel mit Stecker geliefert. Dieses Kabel erfüllt die Sicherheitsanforderungen und sollte an einer vorschriftsmäßigen Schukosteckdose angeschlossen werden, um die Gefahr eines elektrischen Schlages zu vermeiden.Elektrosteckdosen, die nicht richtig verdrahtet sind, können gefährliche Hochspannung an den Metallteilen des switch-Gehäuses verursachen.
Q 4 – Installation Installing a Switch d. 4. About 10 seconds later, the switch is operational: the Input Power LED remains illuminated, the Heartbeat LED flashes steadily, and the two remaining LEDs are extinguished. If the Heartbeat LED blinks steadily about once per second, the POST was successful and you can continue with the installation process. Any other blink pattern indicates that an error has occurred.
Q 4 – Installation Installing a Switch 4.2.4.1 Ethernet Connection To establish an Ethernet connection, do the following: 1. Connect a 10/100 Base-T cross-over cable from an RJ-45 port on the management workstation directly to the RJ-45 Ethernet port; or a 10/100 Base-T straight cable indirectly over an Ethernet network. 2. Log in to the switch with the SANbox Manager application or the Telnet CLI using the default switch IP address 10.0.0.1.
Q 4 – Installation Installing a Switch For Linux: a. Set up minicom to use the serial port. Create or modify the /etc/ minirc.dfl file with the following content: pr pu pu pu portdev/ttyS0 minit mreset mhangup b. Verify that all users have permission to run minicom. Review the / etc/minicom/users file and confirm that the line "ALL" exists or that there are specific user entries. c. Enter the following command at the Linux prompt: minicom For Solaris: a.
Q 4 – Installation Installing a Switch 4.2.6 SANsurfer Management Suite Disk - Windows Installation To install the SANbox Manager application on Windows from the SANsurfer® Management Suite Disk, do the following: 1. 4-10 Close all programs currently running, and Insert the SANsurfer Management Suite Disk into the management workstation CD-ROM drive. If the SANsurfer Management Suite start page does not open in your default browser, do the following: a.
Q 4 – Installation Installing a Switch 4.2.7 SANsurfer Management Suite Disk - Linux Installation To install the SANbox Manager application on Linux from the SANsurfer Management Suite Disk, do the following: 1. Close all programs currently running, and insert the SANsurfer Management Suite Disk into the management workstation CD-ROM drive. If a file browser window opens showing icons for the contents of the CD-ROM, double-click the Start_Here.htm file to open the SANsurfer Management Suite start page.
Q 4 – Installation Installing a Switch 4.2.8 SANsurfer Management Suite Disk - Solaris Installation To install the SANbox Manager application on Solaris from the SANsurfer Management Suite CD-ROM, do the following: 1. Close all programs currently running, and insert the SANsurfer Management Suite Disk into the management workstation CD-ROM drive. If the SANsurfer Management Suite start page does not open in your default browser, do the following: a. Right-click the to open the Workshops Menu. b.
Q 4 – Installation Installing a Switch 4.2.9 SANbox2 Installation Disk - Windows Installation To install the SANbox Manager application on Windows from the SANbox2 Installation Disk, do the following: 1. Close all programs currently running, and insert the SANbox2 Installation Disk into the management workstation CD-ROM drive. 2. Using Windows Explorer, double-click the drive letter which contains the SANbox2 Installation Disk. 3.
Q 4 – Installation Installing a Switch 4.2.12 Configure the Switch Do the following to configure a switch using the SANbox Manager application. Refer to the SANbox2-64 Switch Management User’s Guide for more information about configuring a switch. You can also configure the switch using the CLI. Refer to Appendix B Command Line Interface for more information. 1. Connect to the switch using an Ethernet connection and run SANbox Manager. 2.
Q 4 – Installation Installing a Switch 4.2.13 Configure the Ports Configuring a port involves defining the port mode. For public devices and other switches, a switch automatically sets the port mode as each port discovers the type of device to which it is connected. The default port mode is GL_Port. A GL_Port will self configure as an FL_Port when connected to a loop of public devices or an F_Port when connected to a single device.
Q 4 – Installation Install Firmware 4.3 Install Firmware The switch comes with current firmware installed. You can upgrade the firmware from the management workstation as new firmware becomes available. Firmware installation involves loading the firmware image file onto the switch, unpacking the image file, and then resetting the switch to activate the new firmware. New firmware can be loaded on the switch while the switch is operating without disrupting service.
Q 4 – Installation Install Firmware 4.3.2 Using the CLI to Install Firmware To install firmware using the CLI when an FTP server is present on the management workstation, do the following: 1. Connect to the switch through the Ethernet or the serial port and open a Telnet session. 2. Enter the following account name and password: SANbox2 Login:admin Password: password 3. To start an admin session, enter the following: cli $> admin start 4. Retrieve the firmware file.
Q 4 – Installation Install Firmware 4.3.3 Using FTP and the CLI to Install Firmware To install firmware using the CLI when the management workstation does not have an FTP server, do the following: 1. Connect to the switch through the Ethernet or the serial port. 2. Move to the folder or directory that contains the new firmware image file. 3. Establish communications with the switch using the File Transfer Protocol (FTP). Enter one of the following on the command line: >ftp xxx.xxx.xxx.
Q 4 – Installation Powering Down a Switch 10. Display the list of firmware image files on the switch to confirm that the file was loaded. Refer to the ”Image Command” on page B-15 for more information. cli (admin) $>image list 11. Unpack the firmware image file to install the new firmware in flash memory. cli (admin) $>image unpack filename 12. Reset the switch to activate the new firmware. This will close the Telnet session by default. cli (admin) $>reset 4.
4 – Installation Powering Down a Switch Q Notes 4-20 59043-01 B
Section 5 Diagnostics/Troubleshooting Diagnostic information about the switch is available through the chassis LEDs, the power supply LEDs, and the Port Status LED. Diagnostic information is also available through the SANbox Manager and CLI event logs and error displays. This section describes two types of diagnostics: Power On Self Test (POST) and chassis. POST diagnostics describe the Heartbeat LED and the Port Status LED indications.
Q 5 – Diagnostics/Troubleshooting POST Diagnostics 5.1.1.2 Maintenance Mode Pattern Steady illumination indicates that the switch is in maintenance mode, which returns the switch IP address to 10.0.0.1. From maintenance mode, you may reload firmware, reset the password to the factory default, and remove a corrupt configuration. 5.1.1.3 Internal Firmware Failure Blink Pattern An internal firmware failure blink pattern is 2 blinks per second followed by a two second pause.
Q 5 – Diagnostics/Troubleshooting POST Diagnostics 2. Place the switch in maintenance mode. Press and hold the Maintenance button for about 4 seconds. Refer to ”Recovering a Switch” on page 5-12 for more information about placing the switch in maintenance mode. 3. Establish a Telnet session with the switch using the default IP address 10.0.0.1. telnet 10.0.0.1 4. Enter the account name (prom) and password (prom), and press the Enter key.
5 – Diagnostics/Troubleshooting POST Diagnostics c. Q Activate binary mode and copy the configuration file from the workstation to the switch. The configuration file must be named "configdata". ftp>bin ftp>put configdata d. Close the FTP session. ftp>quit e. Establish communications with the switch using Telnet. Enter one of the following on the command line: telnet xxx.xxx.xxx.xxx or telnet switchname where xxx.xxx.xxx.
Q 5 – Diagnostics/Troubleshooting POST Diagnostics 5.1.2 Port Status LED Indications Port diagnostics for each port are indicated by the Port Status LED as shown in Figure 5-1. Port Status LED Figure 5-1. Port Status LED The Port Status LED has three indications: Logged in - Continuous illumination. Logging in - Flashes at roughly once per second as shown in Figure 5-2. Error - Flashes at roughly twice per second as shown in Figure 5-2. 1 second Logging In Error Figure 5-2.
5 – Diagnostics/Troubleshooting POST Diagnostics Q If a Port Status LED shows an error indication, review the alarm log for messages regarding the affected port. You can inspect the alarm log using the Alarm data tab in SANbox Manager faceplate display or the Show Alarm command. Pertinent alarm log messages will point to one or more of the following conditions: E_Port isolation Excessive port errors 5.1.2.
Q 5 – Diagnostics/Troubleshooting POST Diagnostics 3. Display the active zone set on each switch using the Zoning Active command or the Active Zoneset tab of the SANbox Manager topology display. Compare the zone membership between the two active zone sets. Are they the same? Yes - Contact your authorized maintenance provider. No - Deactivate one of the active zone sets or edit the conflicting zones so that their membership is the same. Reset the port.
5 – Diagnostics/Troubleshooting POST Diagnostics 1. 2. 3. 4. 5-8 Q Examine the alarm configuration for the associated error using the Show Config Threshold command or the SANbox Manager application. Refer to the ”Show Config Command” on page B-58. Refer to Table B-4 for a list of the alarm configuration defaults. Are the thresholds and sample interval correct? Yes - Continue No - Correct the alarm configuration. If the condition remains, continue.
Q 5 – Diagnostics/Troubleshooting Chassis Diagnostics 5.2 Chassis Diagnostics Chassis diagnostics are indicated by the chassis and power supply LEDs as shown in Figure 5-3. Output Power LED (Green) Power Supply Fault LED (Amber) Input Power LED (Green) Fan Fail LED (Amber) Over Temperature LED (Amber) Figure 5-3.
5 – Diagnostics/Troubleshooting Chassis Diagnostics Q 5.2.1 Over Temperature LED is Illuminated The Over Temperature LED illuminates to indicate that the switch logic circuitry is overheating. If the Over Temperature LED illuminates, do the following: 1. 2. Inspect the chassis fans. Are the intake openings clear? Are all fans operating and producing air flow? Yes - Continue. No - Remove any debris from fan intakes and exhausts if necessary. Replace any fan that is not operating.
Q 5 – Diagnostics/Troubleshooting Chassis Diagnostics 5.2.4 Output Power LED Is Extinguished The Output Power LED illuminates to indicate that the power supply is producing the proper voltages. If the Output Power LED is extinguished, do the following: 1. 2. 3. 4. Inspect the Power Supply Fault LED. Is the Power Supply Fault LED illuminated? Yes - Refer to ”Power Supply Fault LED is Illuminated” on page 5-11. No - Continue. Inspect the power cables and connectors.
5 – Diagnostics/Troubleshooting Recovering a Switch Q 5.3 Recovering a Switch A switch can become inoperable or unmanageable for the following reasons: Firmware becomes corrupt IP address is lost Switch configuration becomes corrupt Forgotten password In these specific cases, you can recover the switch using maintenance mode. Maintenance mode returns the switch IP address to 10.0.0.
Q 5 – Diagnostics/Troubleshooting Recovering a Switch 5. The maintenance menu displays several recovery options. To select a switch recovery option, press the corresponding number (displayed in option: field) on the keyboard and press the Enter key. 0) Exit 1) Image Unpack 2) Reset Network Config 3) Reset Password File 4) Copy Log Files 5) Remove Switch Config 6) Remake Filesystem 7) Reset Switch Option: These options and their use are described in the following sections. 5.3.
Q 5 – Diagnostics/Troubleshooting Recovering a Switch 5.3.3 Maintenance – Reset Network Config This option resets the network properties to the factory default values and saves them on the switch. Refer to Table B-6 for the default network configuration values. 5.3.4 Maintenance – Reset Password File This option restores the password for the Admin account name to the default (password) and removes all other user accounts from the switch. 5.3.
Section 6 Removal/Replacement This section describes the removal and replacement procedures for the following field replaceable units (FRU): SFP transceivers CPU module I/O blades Cross-connect blades Power supply modules Fans Table 6-1 describes the marginal operating configurations based on the number of I/O blades and the number of power supply modules.
6 – Removal/Replacement CPU Module Q 6.2 CPU Module The CPU module is equipped with a battery that powers the non-volatile memory. This memory stores the switch configuration. WARNING!! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of the used battery according to the manufacturer’s instructions. WARNUNG!! Bei unsachgemäß ausgetauschter Batterie besteht Explosionsgefahr.
Q 6 – Removal/Replacement CPU Module 6.2.1 Removing the CPU Module To remove the CPU module, do the following: 1. Determine the firmware version. Open a Telnet session and enter the Show Version command to determine the current firmware version. Make note of the firmware version. If the switch is inaccessible, you can obtain the firmware version from another switch in the fabric or records you may have kept. Refer to ”Show Command” on page B-46 for more information. 2.
Q 6 – Removal/Replacement CPU Module 8. To unfasten the CPU module, disconnect the Ethernet and serial cables from the CPU module. Connect an ESD wrist strap to a ground point on the chassis or rack. Using a flat-bladed screwdriver, loosen the four captive screws at the top and bottom of the CPU module faceplate as shown in Figure 6-1. The bottom-left screw is under the latch. CAUTION! The CPU module contains sensitive logic components.
Q 6 – Removal/Replacement CPU Module 6.2.2 Installing the CPU Module To install the CPU module, do the following: 1. Slide the CPU module into the slot guide until it makes contact with the backplane connector. Rotate the blade latch upward to lock the CPU module in place. Fasten the screws. 2. Reconnect the Ethernet and serial cable to the CPU module. 3. Power up the switch. Reconnect both power cords to the power supply modules. 4. Observe the Heartbeat LED. It should blink once per second.
Q 6 – Removal/Replacement CPU Module 8. Load the image file on the switch. Move to the directory that contains the firmware image file and open an FTP session. When prompted, enter the account name (images) and password (images). Enter the Put command and specify the name of the image file. ftp 10.0.0.1 User: images Password: images ftp> binary ftp> put image_file ftp> bye 9. Unpack the image file. Press and hold the Maintenance button for four seconds to place the switch in maintenance mode.
Q 6 – Removal/Replacement I/O Blades 11. Restore switch configuration. Move to the directory that contains the configdata file that you downloaded earlier. Use FTP to upload this file from the management workstation to the switch. ftp 10.0.0.1 User: images Password: images ftp> binary ftp> put configdata ftp> bye 12. Open a Telnet session and enter the Config Restore command to restore the switch configuration. Refer to ”Config Command” on page B-7 for more information.
Q 6 – Removal/Replacement I/O Blades 3. Open a Telnet session and enter the Hotswap command. You can also replace an I/O blade using the SANbox Manager application. Perform the tasks as prompted: Note: The switch will become unresponsive if you do not perform the tasks as prompted. If the switch becomes unresponsive, you must power cycle the switch. SANbox2-64 (admin) #> hotswap This command will guide you through the hotswap process.
Q 6 – Removal/Replacement I/O Blades 7. Using a flat-bladed screwdriver, loosen the captive screws at the top and bottom of the I/O blade faceplate as shown in Figure 6-2. The bottom screw is under the latch. Grasp the latch and press the red release button, then rotate the latch downward to disengage the I/O blade from the backplane connector. Carefully slide the I/O blade out of the slot. Remove all connections from the IO blade in slot 6. Remove the IO blade in slot 6 from the chassis.
Q 6 – Removal/Replacement I/O Blades 9. Slide the I/O blade into the slot guide until it makes contact with the backplane connector. Rotate the blade latch upward to lock the I/O blade in place. Fasten the screws. Insert the IO blade into the chassis in slot 6. Attach all connections, if any, to the IO blade in slot 6. Please confirm that these steps have been accomplished by pressing the ENTER key. 10.
Q 6 – Removal/Replacement Cross-Connect Blades 6.4 Cross-Connect Blades The SANbox2-64 switch contains two CC blades: one in slot 11 (CC blade 0) and the other in slot 12 (CC blade 1) as shown in Figure 6-3. You access slot 11 by removing the top-rear switch cover. To access slot 12, you remove the bottomrear switch cover. Other than this, the procedure for replacing either CC blade is the same. Slot 11 Top-Rear Switch Cover Slot 12 Figure 6-3.
Q 6 – Removal/Replacement Cross-Connect Blades 6.4.1 Removing a CC Blade To remove a CC blade, do the following: 1. Power down the switch. Isolate the switch from the fabric. Open a Telnet session and enter the Shutdown command. Disconnect the power cords from the power supplies. telnet SANbox2 Login: admin Password: password Sanbox2-64 #> admin start Sanbox2-64 (admin) #> shutdown The switch will shutdown. Please confirm (y/n): [n] y Shutdown in progress...
Q 6 – Removal/Replacement Cross-Connect Blades 6. Remove the switch cover. Use a medium crosshead screw driver to remove the four screws on each side and the six screws on top as shown in Figure 6-4. Lift and remove the switch cover and set it aside. Put on an ESD wrist strap and connect it to ground. Figure 6-4. Switch Cover Removal 7. Remove the CC blade. Loosen the six screws (1) that fasten the CC blade to the chassis as shown in Figure 6-5, but do not remove them.
Q 6 – Removal/Replacement Cross-Connect Blades 8. Disconnect the CC blade from backplane. Grasp both latches with the thumbs. Open both latches together a little at a time to disengage the CC blade from the backplane. 9. Lift CC blade from switch. Using the thumbs under the open latches, lift the latch edge of the CC blade up enough to get a better grip. Gently lift the CC blade from the switch. If the CC blade will not come off the screws nearest the backplane, back the screws off a little more.
Q 6 – Removal/Replacement Cross-Connect Blades WARNING!!Two people are required to safely lift and install the switch into a cabinet. To avoid personal injury or damage to the switch, arrange for assistance 5. With an assistant, slide the switch into the rack. Fasten the switch brackets to the rack with screws. 6. Reconnect the Ethernet cable to the CPU module. Reconnect the power cords to the power supply modules to power up the switch. 7. Confirm the power supply module status.
Q 6 – Removal/Replacement Power Supply Modules 6.5 Power Supply Modules The power supply modules are hot pluggable. This means you can remove or install one of the two functioning power supply modules without disrupting service. The power supply modules are also interchangeable; that is, any power supply module will fit in slot #0 or slot #10. 6.5.
Q 6 – Removal/Replacement Power Supply Modules Ground Jack Screw Release Button Latch Screw Figure 6-7. Removing a Power Supply Module 6.5.2 Installing a Power Supply Module To install a power supply module, do the following: 59043-01 B 1. Slide the power supply module into the slot guide until it contacts the backplane. 2. Rotate the blade latch upward to lock the power supply module in place. Fasten the screws. 3.
Q 6 – Removal/Replacement Fans 6.6 Fans The fans are hot pluggable. This means you can remove or install one of the fans while the switch is operating without disrupting service. The fan is completely enclosed, so there is no risk of injury from the fan blades. The fans are also interchangeable; that is, any fan will fit in any bay. Before removing a fan, connect an ESD wrist strap to a ground point on the chassis or rack. 6.6.
Q 6 – Removal/Replacement Fans 6.6.2 Installing a Fan To install a fan, do the following: 59043-01 B 1. Confirm that the new fan has the same air flow direction as the old fan. Each fan has a label indicating the air flow direction. 2. Slide the fan into the bay until it is firmly seated and fasten the screws. A fan will fit in any bay. 3. Confirm the fan status. Do one of the following: Open a Telnet session and enter the Show Chassis command to display the operational status of the fans.
6 – Removal/Replacement Fans Q Notes 6-20 59043-01 B
Appendix A Specifications Appendix A contains the specifications for the SANbox2-64 Fibre Channel switch. Refer to Section 2 General Description for the location of all controls and components. A.1 Performance Fibre Channel Protocols ................. FC-PH Rev. 4.3 FC-PH-2 FC-PH-3 FC-AL Rev 4.5 FC-AL-2 Rev 7.0 FC-FLA FC-GS-3 FC-FG FC-PLDA FC-Tape FC-VI FC-SW-2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4.0 Fibre Channel Classes of Service .. Classes 2 and 3 connectionless Port Types...
A – Specifications Maintainability Q Buffer Credits.................................. 12 buffer credits per port Media Type ..................................... Small Form Pluggable (SFP) optical transceivers. Hot pluggable. 3.3 Volts. Fabric Port Speed ........................... 1.0625 or 2.125 Gigabits/second Maximum Frame Size..................... 2148 bytes (2112 byte payload) System Processor........................... 850 MHz Pentium III® processor Fabric Latency (best case) ............. <0.
Q A – Specifications Fabric Management A.3 Fabric Management Management Methods .................... SANbox Manager Graphical User Interface Application Programming Interface Command Line Interface GS-3 Management Server SNMP FTP Maintenance Connection ................ RS-232 connector; null modem F/F DB9 cable Ethernet Connection ....................... RJ-45 connector; 10/100BASE T cable Switch Agent...................................
A – Specifications Environmental Q A.6 Environmental Temperature Operating .................................. 5 to 40°C (41 to 122°F) Non-operating ........................... - 40 to 70°C (-40 to 158°F) Humidity Operating .................................. 15% to 80%, non-condensing Non-operating ........................... 5% to 90%, non-condensing Altitude Operating .................................. 0 to 3048m (0 to 10,000 feet) Non-operating ...........................
Q A – Specifications Shortwave Laser SFP 1G/2G (multi-mode) A.8 Shortwave Laser SFP 1G/2G (multi-mode) Connector ....................................... Duplex LC Color coding.................................... Beige or black exposed connector surfaces Cable .............................................. Fibre Channel 100-M6-SN-I (50 µm multimode) Fibre Channel 200-M5-SN-I or 200-M6SN-I (62.5 µm multimode) Wavelength..................................... 830 - 860 nm Transmit Power.......................
A – Specifications Longwave Laser SFP 1G/2G (single-mode) Q A.9 Longwave Laser SFP 1G/2G (single-mode) Connector ....................................... Duplex LC Color coding.................................... Blue exposed connector surfaces Cable .............................................. Fibre Channel 100SM-LC-L (9 µm single mode) Wavelength..................................... 1270 - 13.5 nm Transmit Power............................... -10 dBm minimum Receiver Sensitivity ......................
Appendix B Command Line Interface Each switch contains a Telnet server. This server allows a Telnet client to establish a Telnet session with the switch to retrieve information or to configure parameters using the Command Line Interface (CLI). The CLI enables you to perform a variety of fabric and switch management tasks through an Ethernet or a serial port connection. B.
B – Command Line Interface Command Syntax Q B.2 Command Syntax The command syntax is as follows: command keyword keyword [value] keyword [value1] [value2] The Command is followed by one or more keywords. Consider the following rules and conventions: B-2 Commands and keywords are lowercase and case sensitive. Commands with keywords require one of those keywords. Required keyword values appear in standard font: [value]. Optional values are shown in italics: [value].
Q B – Command Line Interface Commands B.3 Commands The command set provides for User and Admin authority levels. User authority grants viewing access to the fabric and switches using the Show command and other read-only commands. Admin authority includes the User authority and grants permission to use the Admin command. The Admin Start command opens an admin session which provides access to the commands that change switch and fabric configurations. Refer to the ”Admin Command” on page B-4.
B – Command Line Interface Admin Command Q Admin Command Opens and closes an Admin session. The Admin session provides commands that change the fabric and switch configurations. Only one Admin session can be open on the switch at any time. An inactive Admin session will time out after a period of time which can be changed using the Set Setup System command. Refer to the ”Set Setup Command” on page B-42.
Q B – Command Line Interface Alias Command Alias Command Creates a named set of ports/devices. Aliases make it easier to assign a set of ports/devices to many zones. An alias can not have a zone or another alias as a member.
B – Command Line Interface Alias Command Q members [alias] Displays all members of the alias given by [alias]. This keyword is available with User authority and does not require a zoning edit session or an admin session. remove [alias] [members] Removes the ports/devices given by [members] from the alias given by [alias]. [members] can have one of the following formats: Domain ID and port number pair (Domain ID, Port Number). Domain IDs and port numbers are in decimal.
Q B – Command Line Interface Config Command Config Command Manages the Fibre Channel configurations on a switch. For information about setting the port and switch configurations, refer to the ”Set Config Command” on page B-28. Authority Admin for all keywords except List Syntax config activate [config] backup cancel copy [config_source] [config_destination] delete [config] edit [config] list restore save [config] Keywords activate [config] Activates the configuration given by [config].
B – Command Line Interface Config Command Q restore Restores configuration settings to an out-of-band switch from a backup file named configdata, which must be first uploaded on the switch using FTP. You create the backup file using the Config Backup command. Use FTP to load the backup file on a switch, then enter the Config Restore command. Note: Configuration archive files created with the SANbox Manager Archive function are not compatible with the Config Restore command.
Q B – Command Line Interface Date Command Date Command This command displays or sets the system date and time. To set the date and time the information string must be provided in this format: MMDDhhmmCCYY. The new date and time takes effect immediately. Authority Admin to change the date; User to display the date. Syntax date [MMDDhhmmCCYY] Keywords [MMDDhhmmCCYY] Specifies the date – this requires an admin session.
Q B – Command Line Interface Fallback Command Fallback Command Loads the fallback version of the firmware from switch memory. The switch stores two versions of the firmware. This command alternately activates the two versions. Authority Admin Syntax Notes fallback Examples The Show Switch command displays the available firmware versions and the currently active version. After executing the Fallback command, reset the switch for the firmware to be placed in effect.
Q B – Command Line Interface Hotswap Command Hotswap Command This command prompts you step-by-step through the procedure to replace an I/O blade, insert an I/O blade, or remove an I/O blade while the switch is running. Authority Admin Syntax Notes hotswap The Hotswap command automatically starts and ends an Admin session in the presence of admin authority. Always perform the hot swap procedure as prompted, otherwise the switch will become unresponsive.
B – Command Line Interface Hotswap Command Q Attach all connections, if any, to the IO blade in slot 6. Please confirm that these steps have been accomplished by pressing the ENTER key. Hotswap IO blade process successfully completed.
Q B – Command Line Interface Help Command Help Command Displays a brief description of the specified command and its keywords. Authority User Syntax Keywords help [command] [keyword] [command] Displays a summary of the command given by [command] and its keywords. If you omit [command], the system displays all available commands from which to choose. [keyword] Displays a summary of the keyword given by [keyword] belonging to the command given by [command].
B – Command Line Interface History Command Q History Command Displays a numbered list of the previously entered commands from which you can re-execute selected commands. Authority User Syntax Notes history Examples Use the History command to provide context for the ! command: Enter ![command] to re-enter the most recent execution of that command.
Q B – Command Line Interface Image Command Image Command Manages and installs switch firmware. Authority Admin Syntax image cleanup fetch [account_name] [ip_address] [file_source] [file_destination] list unpack [file] Keywords cleanup Removes all firmware image files from the switch. All firmware image files are removed automatically each time the switch is reset.
B – Command Line Interface Lip Command Q Lip Command Reinitializes the specified loop port. Authority Admin Syntax Keywords lip [port_number] Examples The following is an example of the Lip command: [port_number] The number of the port to be reinitialized.
Q B – Command Line Interface Passwd Command Passwd Command Changes a user account’s password. Authority Admin to change another account’s password; User to change your own. Syntax Keywords passwd [account_name] Examples The following is an example of the Passwd command: [account_name] The user account name. You must open an admin session to change the password for an account name other than your own.
B – Command Line Interface Ping Command Q Ping Command Initiates an attempt to communicate with another switch in the fabric and reports the result. Authority User Syntax ping ip_address Keywords ip_address The IP address of the switch to query. Examples The following is an example of a successful Ping command: SANbox2 #> ping 10.20.11.57 Ping command issued. Waiting for response... SANbox2 #> Response successfully received from 10.20.11.57.
Q B – Command Line Interface Ps Command Ps Command Displays current system process information. Authority User Syntax Examples ps The following is an example of the Ps command: SANbox2 #> ps PID 59043-01 B PPID %CPU TIME ELAPSED COMMAND 298 292 0.0 00:00:00 59:42 cns 299 292 0.0 00:00:00 59:42 ens 300 292 0.0 00:00:00 59:42 dlog 301 292 0.3 00:00:53 59:42 ds 302 292 0.2 00:00:29 59:42 mgmtApp 303 292 0.0 00:00:02 59:42 nserver 304 292 0.
B – Command Line Interface Quit Command Q Quit Command Closes the Telnet session.
Q B – Command Line Interface Reset Command Reset Command Resets the switch configuration parameters. Authority Admin Syntax reset blade [slot_number] config [config_name] factory port [port_number] snmp switch (default) system zoning Keywords blade [slot_number] Resets the I/O or cross-connect blade that occupies the slot given by [slot_number]. I/O blade slot numbers are 1–4 and 6–9; cross-connect slot numbers are 11–12.
Q B – Command Line Interface Reset Command zoning Clears the zoning database and deactivates the active zone set. The zoning configuration values (autosave, default visibility) remain unchanged. Notes The following tables specify the various factory default settings: Table B-2.
Q B – Command Line Interface Reset Command Table B-3. Port Configuration Defaults (Continued) Parameter Default DeviceScanEnabled True ForceOfflineRSCN False ARB_FF False InteropCredit 0 ExtCredit 0 FANEnable True LCFEnable False MFSEnable True MFS_TOV 10 MSEnable True NoClose False IOStreamGuard Disabled VIEnable False CheckAlps False Table B-4.
Q B – Command Line Interface Reset Command Table B-4. Alarm Threshold Configuration Defaults (Continued) Parameter Default LoginMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 5 1 10 LogoutMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 5 1 10 LOSMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 100 5 10 Table B-5.
Q B – Command Line Interface Reset Command Table B-6. System Configuration Defaults Parameter 59043-01 B Default Ethernet Network Discovery Static Ethernet Network IP Address 10.0.0.1 Ethernet Network IP Mask 255.0.0.0 Ethernet Gateway Address 10.0.0.254 Admin Timeout 30 minutes SecurityEnabled False LocalLogEnabled True RemotelogEnabled False RemoteLogHostAddress 10.0.0.
B – Command Line Interface Set Command Q Set Command Sets a variety of switch parameters. Authority Admin for all keywords except Alarm Clear, Beacon, and Pagebreak which are available with User authority. Syntax set alarm clear beacon [state] blade [slot_number] [state] config [option] log [option] pagebreak [state] port [option] setup [option] switch [state] Keywords alarm clear Clears the alarm log. This keyword is available with User authority.
Q B – Command Line Interface Set Command log [option] Specifies the type of entries to be entered in the event log. Refer to the ”Set Log Command” on page B-38. pagebreak [state] Specifies how much information is displayed on the screen at a time according to the value given by [state]. This keyword is available with User authority. [state] can be one of the following: on Limits the display of information to 20 lines at a time.
Q B – Command Line Interface Set Config Command Set Config Command Sets switch, blade, port, alarm threshold, and zoning configuration parameters. Authority Admin authority and a Config Edit session Syntax set config blade [slot_number] port [port_number] ports [port_number] switch threshold zoning Keywords blade [slot_number] Initiates an edit session in which to change configured administrative state for an I/O or cross-connect blade occupying the slot given by [slot_number].
Q B – Command Line Interface Set Config Command Table B-7. Set Config Port Parameters (Continued) Parameter 59043-01 B Description ISLSecurity E_Port security. Determines which switches a port will establish a link with. Any - link with any FC-SW-2 compliant switch. Ours - link only with an FC-SW-2 compliant QLogic switch. None - reject the link. SymbolicPortName Descriptive name ALFairness Arbitration loop fairness.
Q B – Command Line Interface Set Config Command Table B-7.
Q B – Command Line Interface Set Config Command switch Initiates an editing session in which to change switch configuration settings. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. Table B-8.
Q B – Command Line Interface Set Config Command Table B-8. Set Config Switch Parameters (Continued) Parameter Description PrincipalPriority The priority used in the FC-SW-2 principal switch selection algorithm. 1 is high, 255 is low. ConfigDescription The name for the configuration. The default is undefined. threshold Initiates a configuration session by which to generate and log alarms for selected events.
Q B – Command Line Interface Set Config Command Table B-9. Set Config Threshold Parameters (Continued) Parameter Description Rising Trigger The event count above which a rising threshold alarm is logged. The switch will not generate another rising threshold alarm for that event until the count descends below the falling threshold and again exceeds the rising threshold. Falling Trigger The event count below which a falling threshold alarm is logged.
Q B – Command Line Interface Set Config Command Examples The following is an example of the Set Config Blade command: SANbox2-64 108 (admin-config) #> set config blade 1 A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the default value. If you wish to terminate this process before reaching the end of the list press 'q' or 'qq' and the ENTER key to do so.
Q B – Command Line Interface Set Config Command MFSEnable (True / False) [False ] MFS_TOV (decimal value, 10-20480 msec) [640 ] MSEnable (True / False) [True ] NoClose (True / False) [False ] IOStreamGuard (Enable / Disable) [Disable] VIEnable (True / False) [False ] CheckAlps (True / False) [False ] Finished configuring attributes. This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect.
Q B – Command Line Interface Set Config Command Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
Q B – Command Line Interface Set Config Command The following is an example of the Set Config Zoning command. SANbox2 #> admin start SANbox2 (admin) #> config edit SANbox2 (admin-config) #> set config zoning A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
B – Command Line Interface Set Log Command Q Set Log Command Specifies the type of entries to be entered in the event log. The log is a storage file contained on the switch. The log can hold a maximum of 200 entries. When the log becomes full, the entries are replaced, starting with the oldest entry, to produce a list of the last 200 events which occurred. Log entries are created for ports, components, and event severity levels.
Q B – Command Line Interface Set Log Command None Monitor none of the component events. Other Monitors other miscellaneous events. Port Monitors all port events Switch Monitors switch management events. Zoning Monitors zoning conflict events. level [level] Specifies the severity level given by [level] to use in monitoring events for the specified components or ports. [level] can be one of the following values: Critical Monitors critical events. Warn Monitors warning events.
B – Command Line Interface Set Log Command Q start Starts the logging of events based on the Port, Component, and Level keywords assigned to the current configuration. The logging continues until you enter the Set Log Stop command. stop Stops logging of events. Notes B-40 To maintain optimal switch performance, do not set the Component keyword to All and the Level keyword to Info at the same time.
Q B – Command Line Interface Set Port Command Set Port Command Sets port state and speed for the specified port temporarily until the next switch reset or new configuration activation. This command also clears port counters. Authority Admin Syntax set port [port_number] bypass [alpa] clear enable speed [transmission_speed] state [state] Keywords [port_number] Specifies the port. Ports are numbered beginning with 0.
Q B – Command Line Interface Set Setup Command Set Setup Command Changes SNMP and system configuration settings. The switch maintains one SNMP configuration and one system configuration. Authority Admin Syntax set setup snmp system Keywords snmp Prompts you in a line-by-line fashion to change SNMP configuration settings. Table B-11 describes the SNMP fields. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. Table B-11.
Q B – Command Line Interface Set Setup Command Table B-11. SNMP Configuration Settings Entry Description TrapCommunity Trap community password that authorizes an SNMP agent to receive traps. This is a write-only field. The value on the switch and the SNMP management server must be the same. The default is “public”. AuthFailureTrap Enables (True) or disables (False) the generation of traps in response to trap authentication failures. The default is False.
Q B – Command Line Interface Set Setup Command Notes The two components of security are user authentication and fabric security. The user must be authenticated before gaining access to a switch. If an invalid account name/password combination is entered, that user can not access the switch, and thus can not gain access to the fabric.
Q B – Command Line Interface Set Setup Command Trap4Version (1 / 2) [2 ] Trap4Enabled (True / False) [False ] Trap5Address (dot-notated IP Address) [0.0.0.
Q B – Command Line Interface Show Command Show Command Displays fabric, switch, and port operational information.
Q B – Command Line Interface Show Command chassis Displays chassis component status and temperature. config [option] Displays switch and port configuration attributes. Refer to the ”Show Config Command” on page B-58. domains Displays list of each domain and its worldwide name in the fabric. donor Displays list of current donor configuration for all ports. fabric Displays list of each domain, fabric ID, worldwide name, node IP address, and port IP address.
Q B – Command Line Interface Show Command pagebreak Displays the current pagebreak setting. The pagebreak setting limits the display of information to 20 lines (On) or allows the continuous display of information without a break (Off). panel Displays the hardware configuration and port mapping for a switch. The representation of the faceplate indicates power supply modules (PS), I/O blades (IO), and CPU module (CPU). perf [option] Displays performance information for all ports.
Q B – Command Line Interface Show Command Table B-13. Show Port Parameters (Continued) Entry 59043-01 B Description LIP_AL_PD_AL_PS Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets, performed. LIP_F7_AL_PS This LIP is used to reinitialize the loop. An L_port, identified by AL_PS, may have noticed a performance degradation and is trying to restore the loop. LIP_F8_AL_PS This LIP denotes a loop failure detected by the L_port identified by AL_PS.
Q B – Command Line Interface Show Command Table B-13. Show Port Parameters (Continued) Entry Description TotalOfflineSeq Total number of Offline Sequences issued by this port. TotalRxFrames Total number of frames received by this port. TotalRxWords Total number of words received by this port. TotalTxFrames Total number of frames issued by this port. TotalTxWords Total number of words issued by this port. TxLinkResets Number of Link Resets issued by this port.
Q B – Command Line Interface Show Command Ps Show (About, Alarm, Backtrace, Chassis, Config Port, Config Switch, Config Threshold, Dev, Dev Settings, Domains, Donor, Fabric, Log, Log Settings, Lsdb, Mem, Ns, Perf, Port, Setup Mfg, Setup Snmp, Setup System, Steering, Switch, Topology, Users) Uptime User Accounts Whoami Zoneset (Active, List) Zoning (History, Limits, List) switch Displays switch operational information. topology Displays all connected devices.
Q B – Command Line Interface Show Command FanStatus (1) Good FanStatus (2) Good FanStatus (3) Good PowerSupplyStatus (1) NotInstalled PowerSupplyStatus (2) NotInstalled HeartBeatCode 1 HeartBeatStatus Normal User Ports Map -------------(displays Non Real-Time data for slot # and blade type-instance) SL#0 SL#1 SL#2 SL#3 SL#4 SL#5 SL#6 SL#7 SL#8 SL#9 SL#10 PS-0 IO-0 IO-1 IO-2 IO-3 CPU-0 IO-4 IO-5 IO-6 IO-7 PS-1 -------------------------------------------------------------
Q B – Command Line Interface Show Command The following is an example of the Show Panel command: SANbox2 #> show panel User Ports Map -------------(displays Non Real-Time data for slot # and blade type-instance) SL#0 SL#1 SL#2 SL#3 SL#4 SL#5 SL#6 SL#7 SL#8 SL#9 SL#10 PS-0 IO-0 IO-1 IO-2 IO-3 CPU-0 IO-4 IO-5 IO-6 IO-7 PS-1 -----------------------------------------------------------------* 0 8 16 24 * 32 40 48 56 * * 1 9 17 25 * 33 41 49 57 * * 2 10 18 26 *
Q B – Command Line Interface Show Command The following is an example of the Show Interface command: SANbox2 #> show interface eth0 Link encap:Ethernet HWaddr 00:C0:DD:00:BD:ED inet addr:10.20.68.107 Bcast:10.20.68.255 UP BROADCAST RUNNING MULTICAST MTU:1500 Mask:255.255.255.0 Metric:1 RX packets:4712 errors:0 dropped:0 overruns:0 frame:0 TX packets:3000 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:415313 (405.5 Kb) TX bytes:716751 (699.
Q B – Command Line Interface Show Command Class3FramesOut 0 LIP_F8_AL_PS 0 TotalRxFrames 0 Class3Toss 0 LIP_F8_F7 0 TotalRxWords 0 Class3WordsIn 0 LinkFailures 0 TotalTxFrames 0 Class3WordsOut 0 Login 0 TotalTxWords 0 DecodeErrors 0 Logout 0 TxLinkResets 0 EpConnects 0 LoopTimeouts 0 TxOfflineSeq 0 FBusy 0 LossOfSync 0 TxWaits 0 The following is an example of the Show Slot command: SANbox2 #> show slot Slot 59043-01 B Blade Port Blade Diag Temp Credit Numb
Q B – Command Line Interface Show Command The following is an example of the Show Switch command: SANbox2 #> show switch Switch Information -----------------SymbolicName SANbox2-203 SwitchWWN 10:00:00:c0:dd:00:b8:b5 SwitchType SANbox2-64 PromVersion V0.1-5-18 CreditPool 0 DomainID 3 FirstPortAddress 640000 FlashSize - MBytes 128 LogLevel Info MaxPorts 16 NumberOfResets 127 ReasonForLastReset NormalReset SWImageVersion (1) - build date V1.
Q B – Command Line Interface Show Command The following is an example of the Show Topology command for port 4: SANbox2 #> show topology 4 Local Link Information ---------------------PortNumber 4 PortID 010400 PortWWN 20:04:00:c0:dd:00:90:f3 PortType F Remote Link Information ----------------------Device 0 PortID 010400 PortWWN 21:00:00:e0:8b:07:a8:bc NodeWWN 20:00:00:e0:8b:07:a8:bc PortType N Description (NULL) IPAddress 0.0.0.
Q B – Command Line Interface Show Config Command Show Config Command Displays switch, I/O blade, port, alarm threshold, and zoning attributes for the current configuration. Authority User Syntax show config blade [slot_number] port [port_number] switch threshold zoning Keywords blade [slot_number] Displays configuration parameters for the I/O blade or cross-connect blade that occupies the slot given by [slot_number].
Q B – Command Line Interface Show Config Command FANEnable False LCFEnable False MFSEnable False MFS_TOV 640 MSEnable False NoClose False IOStreamGuard False VIEnable False CheckAlps False The following is an example of the Show Config Switch command: SANbox2 #> show config switch Configuration Name: default ------------------- Switch Configuration Information -------------------------------AdminState Online BroadcastEnabled True InbandEnabled True DomainID 100 (0x64) DomainIDL
Q B – Command Line Interface Show Config Command RisingTrigger 25 FallingTrigger 1 SampleWindow 10 DecodeErrorsMonitoringEnabled True RisingTrigger 25 FallingTrigger 0 SampleWindow 10 ISLMonitoringEnabled True RisingTrigger 2 FallingTrigger 0 SampleWindow 10 LoginMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LogoutMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LOSMonitoringEnabled True RisingTrigger 100 FallingTrigg
Q B – Command Line Interface Show Log Command Show Log Command Displays the contents of the log or the parameters used to create entries in the log. The log contains a maximum of 200 entries. When the log reaches its entry capacity, subsequent entries overwrite the existing entries, beginning with the oldest. Authority User Syntax show log component level options port settings Keywords component Displays the components currently being monitored for events.
Q B – Command Line Interface Show Log Command The following is an example of the Show Log Options command: SANbox2 #> show log options Allowed options for log ----------------------component All,None,NameServer,MgmtServer,Zoning,Switch, Chassis,Blade,Port,Eport,Snmp,Other level Critical,Warn,Info,None The following is an example of the Show Log command: [327][day month date time year][I][Eport:0xdd00b8b6.304.
Q B – Command Line Interface Show Perf Command Show Perf Command Displays port performance in frames/second and bytes/second. If you omit the keyword, the command displays data transmitted (out), data received (in), and total data transmitted and received in frames/second and bytes per second.
Q B – Command Line Interface Show Perf Command errors [port_number] Displays continuous error counts for the set of 16 ports that include [port_number]. Type “q” and press the Enter key to stop the display.
Q B – Command Line Interface Show Setup Command Show Setup Command Displays the current SNMP and system settings. Authority User Syntax show setup mfg snmp system Keywords mfg Displays manufacturing information about the switch. snmp Displays the current SNMP settings. system Displays the current system settings.
Q B – Command Line Interface Show Setup Command The following is an example of the Show Setup Snmp command: SANbox2 #> show setup snmp SNMP Information ---------------- B-66 Contact Location N_107 System Test Lab Description QLogic SANbox2 FC Switch Trap1Address 10.0.0.254 Trap1Port 162 Trap1Severity warning Trap1Version 2 Trap1Enabled False Trap2Address 0.0.0.0 Trap2Port 162 Trap2Severity warning Trap2Version 2 Trap2Enabled False Trap3Address 0.0.0.
Q B – Command Line Interface Show Setup Command The following is an example of the Show Setup System command: SANbox2 #> show setup system System Information ------------------ 59043-01 B Eth0NetworkDiscovery Static Eth0NetworkAddress 10.20.11.32 Eth0NetworkMask 255.255.252.0 Eth0GatewayAddress 10.20.8.254 AdminTimeout 30 SecurityEnabled False LocalLogEnabled True RemoteLogEnabled False RemoteLogHostAddress 10.0.0.
B – Command Line Interface Shutdown Command Q Shutdown Command Terminates all data transfers on the switch at convenient points and closes the Telnet session. Always power cycle the switch after entering this command. Authority Admin Syntax Notes shutdown B-68 Always use this command to effect an orderly shut down before removing power from the switch. Failure to do so could corrupt the flash memory and the switch configuration.
Q B – Command Line Interface Test Command Test Command Tests I/O blades and ports using internal (SerDes level), external (SFP), and online loopback tests. Internal and external tests require that the port be placed in diagnostic mode. Refer to the ”Set Command” on page B-26 for information about changing the I/O blade or port administrative state. While the test is running, the remaining ports on the switch remain fully operational.
Q B – Command Line Interface Test Command 3. Choose the type of port loopback test to run: To run an internal loopback test, enter the following: test x internal To run an external loopback test, insert a loopback plug into the SFP on the selected port, then enter the following command: test x external 4. A series of test parameters are displayed on the screen. Press the Enter key to accept each default parameter value, or type a new value for each parameter and press the Enter key.
Q B – Command Line Interface Test Command 3. A series of test parameters are displayed on the screen. Press the Enter key to accept each default parameter value, or type a new value for each parameter and press the Enter key. The TestLength parameter is the number of frames sent, the FrameSize (256 byte maximum in some cases) parameter is the number of bytes in each frame, and the DataPattern parameter is the pattern in the payload.
Q B – Command Line Interface Uptime Command Uptime Command Displays the elapsed time since the switch was last reset and reset method.
Q B – Command Line Interface User Command User Command Administers or displays user accounts. Authority Admin. The List keyword is available with User authority. Syntax user accounts add delete [account_name] list Keywords accounts Displays all user accounts that exist on the switch. add Add a user account to the switch. After this command is executed, the administrator will be prompted for the information needed to establish the user account. A switch can have a maximum of 15 user accounts.
Q B – Command Line Interface User Command The following is an example of the User Add command: SANbox2 (admin) #> user add Press 'q' and the ENTER key to abort this command.
Q B – Command Line Interface Whoami Command Whoami Command Displays the account name, session number, and switch domain ID for the Telnet session.
B – Command Line Interface Zone Command Q Zone Command Manages zones and zone membership on a switch. Authority Admin authority and a Zoning Edit session. Refer to the ”Zoning Command” on page B-83 for information about starting a Zoning Edit session. The List, Members, and Zonesets keywords are available with User authority and do not require a Zoning Edit session.
Q B – Command Line Interface Zone Command list Displays a list of all zones and the zone sets of which they are members. This keyword is valid for User authority and does not require a zoning edit session. members [zone] Displays all members of the zone given by [zone]. This keyword is available with User authority and does not require a Zoning Edit session. remove [zone] [members] Removes the ports/devices given by [members] from the zone given by [zone].
Q B – Command Line Interface Zone Command Examples The following is an example of the Zone List command: SANbox2 #> zone list Zone ZoneSet ------------------wwn_b0241f zone_set_1 wwn_23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example of the Zone Members command: SANbox2 #> zone members wwn_b0241f Current List of Members for Zone: wwn_b0241f ----
Q B – Command Line Interface Zone Command The following is an example of the Zone Zonesets command: SANbox2 #> zone zonesets zone1 Current List of ZoneSets for Zone: wwn_b0241f ---------------------------------zone_set_1 59043-01 B B-79
B – Command Line Interface Zoneset Command Q Zoneset Command Manages zone sets and zone set membership across the fabric. Authority Admin authority and a Zoning Edit session. Refer to the ”Zoning Command” on page B-83 for information about starting a Zoning Edit session. The Active, List, and Zones keywords are available with User authority. You must close the Zoning Edit session before using the Activate and Deactivate keywords.
Q B – Command Line Interface Zoneset Command delete [zone_set] Deletes the zone set given by [zone_set]. If the specified zone set is active, the command is suspended until the zone set is deactivated. This keyword requires a Zoning Edit session. list Displays a list of all zone sets. This keyword is available with User authority and does not require a Zoning Edit session. remove [zone_set] [zone_list] Removes a list of zones given by [zone_list] from the zone set given by [zone_set].
B – Command Line Interface Zoneset Command Q The following is an example of the Zoneset Zones command: SANbox2 #> zoneset zones ssss Current List of Zones for ZoneSet: ssss ---------------------------------zone1 zone2 zone3 B-82 59043-01 B
Q B – Command Line Interface Zoning Command Zoning Command Opens a Zoning Edit session in which to create and manage zone sets and zones. Refer to the ”Zone Command” on page B-76 and the ”Zoneset Command” on page B-80. Authority Admin. The List keyword is available with User authority. Syntax zoning active cancel clear edit history limits list restore save Keywords active Displays membership information for the active zone set including member zones and zone members.
Q B – Command Line Interface Zoning Command limits Displays the maximum limits imposed on the zoning database for the number of zone sets, zones, aliases, members per zone, members per alias, and total members. list Lists all fabric zoning definitions. This keyword is available with User authority. restore Reverts the changes to the zoning database that have been made during the current Zoning Edit session since the last Zoning Save command was entered.
Q B – Command Line Interface Zoning Command 50:06:04:82:bf:d2:18:c2 50:06:04:82:bf:d2:18:d2 10:00:00:00:c9:23:bd:31 wwn_221416 50:06:04:82:bf:d2:18:c2 50:06:04:82:bf:d2:18:d2 10:00:00:00:c9:22:14:16 wwn_2215c3 50:06:04:82:bf:d2:18:c2 50:06:04:82:bf:d2:18:d2 10:00:00:00:c9:22:15:c3 Configured Zoning Information ZoneSet Zone ZoneMember -------------------------------wwn wwn_b0241f 50:06:04:82:bf:d2:18:c2 50:06:04:82:bf:d2:18:d2 21:00:00:e0:8b:02:41:2f wwn_23bd31 50:06:04:82:bf:d2:18:c2 50:06:04:82:b
B – Command Line Interface Zoning Command Q Notes B-86 59043-01 B
Glossary Activity LED A port LED that indicates when frames are entering or leaving the port. Class 3 Service A service which multiplexes frames at frame boundaries to or from one or more N_Ports without acknowledgment. Alias A collection of objects that can be zoned together. An alias is not a zone, and can not have a zone or another alias as a member. Domain ID User defined name that identifies the switch in the fabric. AL_PA Arbitrated Loop Physical Address E_Port Expansion port.
Q Frame Data unit consisting of a start-of-frame (SOF) delimiter, header, data payload, CRC, and an end-of-frame (EOF) delimiter. FRU Field Replaceable Unit Heartbeat LED A chassis LED that indicates the status of the internal switch processor and the results of the Power-On Self-Test. Initiator The device that initiates a data exchange with a target device. In-Order-Delivery A feature that requires that frames be received in the same order in which they were sent.
SANbox2-64 Fibre Channel Switch Installation Guide SFF Small Form-Factor transceiver. SFP Small Form-Factor Pluggable. A transceiver device, smaller than a GigaBit Interface Converter, that plugs into the Fibre Channel port. Q Zone Set A set of zones grouped together. The active zone set defines the zoning for a fabric. Small Form Factor A transceiver device, smaller than a GigaBit Interface Converter, that is permanently attached to the circuit board.
Q SANbox2-64 Fibre Channel Switch Installation Guide Notes Glossary-4 59043-01 B
Index A access 3-8 Access Control List zone 3-9 account name 3-11, B-1, B-75 ACL - See Access Control List Activity LED 2-11 Admin authority 3-11, B-3 Admin command B-4 administrative state blade B-26 port B-41 switch B-27 air flow 2-14, A-4 alarm configuration B-32 configuration display B-58 log B-26, B-46 alias add members B-5 copy B-5 create B-5 delete B-5 delete members B-6 display list B-5 display members B-6 rename B-6 Alias command B-5 altitude A-4 Arbitrated Loop Physical Address 3-1, B-41 authority
Q SANbox2-64 Fibre Channel Switch Installation Guide F serial port 2-12 credits 3-6, A-2 cross-connect blade description 6-11 installation 6-14 removal 6-12 D Date command B-9 device cabling 4-15 description 3-1 diagnostics 5-1, A-2 dimensions A-3 distance 3-6 domain ID 3-4, 5-6 domain ID lock 3-4 domains B-47 donor port 3-6, B-47 E E_Port 2-10, 5-6 emissions standards A-4 environmental conditions 4-2 specifications A-4 Ethernet LEDs 2-11 port 2-11 event logging by component B-38, B-61 by port B-39, B-
Q SANbox2-64 Fibre Channel Switch Installation Guide G G_Port 2-9 GBIC - See GigaBit Interface Converter generic ports 2-9 Gigabit Interface Converter 3-1 GL_Port 2-9 H hard zone 3-8 harmonics A-4 HBA - See Host Bus Adapter Heartbeat LED 2-6, 5-1 Help command B-13 History command B-14 host bus adapter 3-1 Hotswap command B-11 humidity 4-2, A-4 HyperTerminal application 4-8 I I/O blade 2-7 configuration B-28 installation 6-9 removal 6-7 reset B-21 Image command B-15 immunity A-4 Input Power LED 2-6, 5-10
Q SANbox2-64 Fibre Channel Switch Installation Guide Over Temperature LED 2-7, 5-10 P page break B-27 Passwd command B-17 password change B-17 file reset 5-14 restore default 5-14 switch B-17 user account 3-11, B-1 performance 3-6 Ping command B-18 planning 3-1 port activity 2-8 administrative state B-41 buffer credits 3-6 configuration 4-15, B-28 configuration display B-58 counters B-41 diagnostics 5-5 Ethernet 2-11 external test B-69 Fibre Channel 2-7 generic 2-9 initialize B-21 internal test B-69 logg
Q SANbox2-64 Fibre Channel Switch Installation Guide SFP - See Small Form-Factor Pluggable Show command B-46 Show Config command B-58 Show Log command B-61 Show Perf command B-63 Show Setup command B-65 Shutdown command B-68 Simple Network Management Protocol configuration B-42 configuration display B-65 description 2-15 reset B-21 site requirements 4-1 slot number 2-3, B-50 small form-factor pluggable 2-8, 6-1 SNMP - See Simple Network Management Protocol soft zone 3-9 steering B-50 switch administrative
Q SANbox2-64 Fibre Channel Switch Installation Guide list B-77 list members B-77 name server 3-9 rename B-77 type B-77 Virtual Private Fabric 3-10 Zone command B-76 zone set activate B-80 active B-83 add member zone B-80 copy B-80 create B-80 deactivate B-22, B-80 delete B-81 delete member zone B-81 display B-81 display active B-80 display members B-81 display zones B-77 rename B-81 Zoneset command B-80 zoning configuration B-33 configuration display B-58 database B-22 edit B-83 history B-83 limits 3-8, B