User`s guide

3
Known Issues with Brocade/SANbox2 operation:
The SANbox2 switch supports 2 modes of treating devices when there is no
active zoneset, either visible to each other or visible to none. When operating with
a Brocade switch, the SANbox2 switch should be set to no orphan visibility. Do
this by using the CLIsh command “set config zoning” to set “Default” to “None”.
When zoning, the SANbox2 allows you to specify zone members as WWNs,
domain/portNos, or by Fibre Channel address. Brocade switches accept only the
WWN specification.
Do not enable Brocade's Platform Management Server. It should be disabled by
default. If it is enabled, the Brocade switch will keep sending non-GS-3
management server messages to E_port every 4 seconds and the Brocade switch
will eventually isolate with the message “WARNING MS-PLDBSEG…MS
Platform Segmented”. To disable this feature, follow these steps:
switch:admin>msPlMgmtDeactivate
switch:admin> msplatshow
Platform Management is NOT enabled.
Brocade Silkworm 3800; Firmware supported: 3.0.2a
Configuring the Brocade 3800 switch:
Certain configuration parameters need to be set on the Brocade switch before it will
operate with a standards compliant switch. The following commands must be entered
from the Brocade telnet interface.
switch:admin> switchdisable
switch:admin> interopmode 1
switch:admin> fastboot
In a mixed fabric with SANbox2, Brocade and McData switches, Domain IDs must
be in the 0x61-7f range. If a SANbox 1Gb switch is in the fabric, this is further
restricted to 0x61-6f or 70-7f.The Domain ID can be set with the Brocade telnet
interface.
switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (97..127) [97]