Installation guide
2
New Features in 1.5.1
Version 1.5.1.04, and later, adds the following features:
SCSI Probe Enable/Disable – Enables or disables nameserver device probe for
FC4 descriptors. This can be configured on a per-port basis in CLIsh via the
DeviceScanEnable parameter in “set config port” from “config edit” mode.
Force Offline RSCNs Immediately – Allows configuration of RSCN delivery
for port offlines. Default behavior is to delay a minimum of 200msec before a
RSCN is sent when a port goes offline. To configure this to send that RSCN
immediately when a port goes offline, set ForceOfflineRSCN to True in the
CLIsh “set config port” from “config edit” mode.
SNMP V1 Trap Support – Prior releases support V2 traps. This release adds
support for V1 traps as well. The trap version is specified for each trap address.
To select the version, set trapVersion in the CLIsh “set setup snmp” command.
SNMP Proxy Disable – This release adds the ability to turn off in-band SNMP
proxy via the ProxyEnabled parameter in the CLIsh “set setup snmp” command.
Ping from Command Line Interface (CLI) – Added the ability to send an
ICMP ECHO request to another host or switch. From CLIsh, run “ping <IP
address>”.
Date/Time without Reset – In previous releases, you would have to reset the
switch after changing the date. With this release, the switch reads the hardware
clock automatically after a date change.
IP Configuration – Change the order the IP info is entered for “set setup
system”. Don’t prompt for IP address, netmask, or gateway if the discovery
method isn’t “Static”. Disable some of the static IP fields depending on the
network discovery protocol selected.
Documentation
Installation, setup and management of the SANbox2 switch are described in the
following manuals. These manuals are available on the distribution CD or on-line at
support@qlogic.com
.
• SANbox2-64 Fibre Channel Switch Installation Guide, 59043-01 B
• SANBox2-64 Switch Management User's Guide 59048-01 B
• SANbox2-8c Fibre Channel Switch Installation Guide 59042-02 B
• SANbox2-16 Fibre Channel Switch Installation Guide 59021-05 B
• SANbox2-8c/16 Switch Management User's Guide 59022-05 B
• SANbox2 Simple Network Management Protocol Reference Guide 59047-00 A
• SANbox2-64 Field Replaceable Unit Installation Guide 59049-01 A
• SANbox2-64 Chassis Replacement Guide 59050-00 A
• SANbox2-64 Rack Mounting Guide 59051-00 A
The following manual is available on-line at www.qlogic.com/interopguide:
• QLogic Switch Interoperability Guide SN0135524-00 A