FC Port Diagnostics
59229-05 A 4-9
E_Port Isolation
A Logged-In LED error indication is often the result of E_Port isolation. An isolated 
E_Port is indicated by a red link in the Enterprise Fabric Suite 2007 topology 
display. E_Port isolation can be caused by the following:
 Security failure
 FL_Port is connected to another switch
 Conflicting domain IDs
 Conflicting timeout values
 Conflicting zone membership between active zone sets
Refer to the SANbox 9000 Series Enterprise Fabric Suite 2007 User Guide or the 
SANbox 9000 Series Stackable Chassis Switch Command Line Interface Guide 
for information about how to change domain IDs, timeout values, and edit zoning. 
Review the event browser and do the following to diagnose and correct an 
isolated E_Port:
1. Does the event browser show an invalid attach alarm for the affected port?
 Yes - Review the ISL group in the active security set to ensure that the 
membership includes the necessary ports and that the secrets on all 
switches are correct.
 No - Continue.
2. Does the event browser show a repeating alarm about an unsupported 
E_Port command on the affected port?
 Yes - The port is configured as an FL_Port and connected to another 
switch. Correct the port connection or the port type.
 No - Continue.
3. Display the fabric domain IDs using the Show Domains command or the 
Switch data tab in the Enterprise Fabric Suite 2007 topology display. Are all 
domain IDs in the fabric unique?
 Yes - Continue.
 No - Correct the domain IDs on the offending switches using the Set 
Config Switch command or the Enterprise Fabric Suite 2007 Switch 
Properties window. Reset the port. If the condition remains, continue.