Power-On-Self-Test (POST)
SANbox-8 Fibre Channel Switch
3-4 Diagnostics/Troubleshooting 59008-03 Rev. A Installer’s/User’s Manual
The POST diagnostic program performs the following basic tests:
• checksum tests on the Boot firmware located in a PROM and the main
Switch firmware located in FLASH memory
• functional hardware tests on internal Switch memory
• various read/write register and loopback data-path tests on the Switch logic
• Frame Bus and Auto Route logic tests
• Switch Management port logic
• Arbitrated Loop tests
Heartbeat LED Blink Patterns
Normal (all pass)
If all POST diagnostics pass, the Switch will go to normal operation and the Heart-
beat LED will blink at a steady rate of one (1) blink per second.
Failure Blink Patterns
The Heartbeat LED indicates the error by blinking a series of blinks, pausing for
three seconds, then repeating the blinks. The number of blinks between the three-
second pauses indicates the error. The blinks are at about twice the speed of the
normal Heartbeat.
Test/Failure Descriptions
If any POST errors occur, notify QLogic Customer Support or your autho-
rized maintenance provider.
The following paragraphs describe the tests and their failure indication. Refer to
Appendix B QLogic Customer Support for information about how to contact
QLogic Customer Support.
3 Seconds1 Second