User`s manual
Table Of Contents
- Preface
- General Description
- Installation
- Introduction
- Unpack
- Place or Mount the Equipment
- Apply the IEC Class 1 Laser Information Label (If the installation is in Europe)
- Install GBICs
- Connect to AC Power
- Switch Logic Power Good LED
- Check the Power-On-Self-Test (POST) Results
- Cable Fibre Channel Devices to the Switch
- Configure the Chassis
- Configure the Ports
- Zoning
- Rack and Shelf Administration
- Operating the Switch
- Diagnostics/Troubleshooting
- Removal/Replacement Procedures
- Multi-Chassis Fabrics
- Reference Information
- QLogic Customer Support
- Index

Preliminary
Cable Fibre Channel Devices to the Switch
SANbox-8 Fibre Channel Switch
2-14 Installation 59008-03 Rev. A Installer’s/User’s Manual
Private Segmented Loop Connections
Figure 2-6 shows the connection of Private Loop servers and Private Loop storage
units. Each SL_Port is one segment of a segmented loop. Each segmented loop
may be divided into a maximum of 33 segments. Use Switch management to
configure the appropriate ports to SL mode and to link SL_Ports (segments) into
segmented loops. For example you could have Server 1 and the RAID on one
segmented loop and the remainder of the servers and the JBODs on another
segmented loop. Remember that these private devices cannot communicate
between private loops through the Switch, only within their segmented loop.
Figure 2-6 Private Segmented Loop Connections
Rx
Tx
Rx
Tx
RxTx
1
Rx
Tx
2
3 5
7
Tx
Rx
Tx
Rx
SL_Port
4
SL_Port
SL_Port
SL_Port
Tx
Rx
SL_Port
SL_Port
SL_Port
Rx
Tx
Rx
Tx
Tx
Rx
8
Tx
Rx
Tx
Rx
6
Tx
Rx
Tx
Rx
SL_Port
1 2 3 4
Local Area Network (LAN)
Private Loop
Storage Servers
Controller
JBOD 1
JBOD 2
JBOD 3
Private Loop
Storage Units
RAID