User`s manual

Table Of Contents
Preliminary
Major Fibre Channel Port Features
SANbox-8 Fibre Channel Switch
1-4 General Description 59008-03 Rev. A Installer’s/User’s Manual
Figure 1-2 Segmented Loop Topology Example
Segmented Loop Features
Switch management allows you to designate any or all ports on a SANbox-8
chassis as SL_Ports.
SL_Ports connect to devices that conform to the Fibre Channel-Private Loop
SCSI Direct Attach (FC-PLDA) standard. If you place a Public Fibre
Channel device on an SL_Port it becomes a Private device and (like other
Private devices) cannot communicate off the loop.
Each SL_Port can support up to 126 devices.
Each SL_Port automatically discovers the devices connected to it.
Switch management allows you to link up to 32 segments (SL_Ports)
together in the same segmented loop zone (even across multiple chassis in
the same fabric) to form a Segmented Private Loop. The aggregate total
number of devices in the linked SL_Ports must not exceed 126 devices and
all AL_PAs within the linked segments must be unique.
Devices in the same segmented loop zone communicate with one another as
though they were on the same physical loop.
Devices on SL_Ports cannot communicate with devices on F, FL or
TL_Ports. They also cannot communicate with devices on SL_Ports which
are not in the same segmented loop zone.
Devices connected to SL_Ports are not registered with the Name Server.
Private Loop
Segment
Hub
SL_Port
Private Loop
Segment
Private Loop
Segment
Hub
SL_Port
SL_Port
Hub
ST3
ST2
ST1
Switch
Server 3
Server 2