User`s manual
Table Of Contents
- Preface
- General Description
- Installation
- Introduction
- Unpack
- Place or Mount the Equipment
- Apply the IEC Class 1 Laser Information Label (If the installation is in Europe)
- Install GBICs
- Connect to AC Power
- Switch Logic Power Good LED
- Check the Power-On-Self-Test (POST) Results
- Cable Fibre Channel Devices to the Switch
- Configure the Chassis
- Configure the Ports
- Zoning
- Rack and Shelf Administration
- Operating the Switch
- Diagnostics/Troubleshooting
- Removal/Replacement Procedures
- Multi-Chassis Fabrics
- Reference Information
- QLogic Customer Support
- Index

Preliminary
SANbox-8 Switch Specifications
SANbox-8 Fibre Channel Switch
Installer’s/User’s Manual 59008-03 Rev. A Reference Information A-5
Non Operating Vibration:...................(In any axis): 0.5G from 10 to 300 Hz
Non Operating Shock:........................(In any axis): 8.0G for 15 m seconds
Switch Regulatory Standards Certified to:
Safety Standards: ...............................UL1950
CSA 22.2 No. 950
EN60950
Emissions Standards: .........................FCC Part 15B Class A
VCCI Class A ITE
CISPR 22, Class A
EN 55022, Class A
Voltage Fluctuations: .........................EN 61000-3-3
Harmonics:.........................................EN 61000-3-2
Immunity:...........................................EN 50082-1:1997
Marking:.............................................FCC Part 15
UL (United States)
UL (Canada)
TUV
VCCI
CE
For more information refer to “Communications Statements” in the Preface.
Shortwave Laser GBIC (multi-mode)
Connector:..........................................Duplex SC
Color coding: .....................................Beige or black exposed connector surfaces
Cable:.................................................Fibre Channel 100-M5-SN-I or
100-M5-SL-I (50um multimode)
Fibre Channel 100-M6-SN-I or
100-M6-SL-I (62.5um multimode)
Wavelength:........................................770 - 860 nm
Open Fiber Control:...........................GBIC modules are standard with No-OFC.
GBIC modules with OFC are only qualified
from IBM® as SOC-1063.
Transmit Power: .................................-10dBm average
Receiver Sensitivity: ..........................-16dBm average