User`s guide
Table Of Contents
- Table of Contents
- 1 Introduction
- 2 General Description
- 3 Planning
- 4 Installation
- Site Requirements
- SANbox 6142 Router Installation
- Pre-installation Check List
- Mount the Router
- Install the Transceivers
- Connect the Management Workstation to the Router
- Configure the Management Workstation
- Install SANsurfer iSCSI/FC Router Manager
- Start SANsurfer iSCSI/FC Router Manager
- Connect the Router to AC Power
- Configure the Router
- Cable Devices to the Router
- Firmware Installation
- 5 Diagnostics and Troubleshooting
- 6 Removal/Replacement
- 7 SANsurfer iSCSI/FC Router Manager
- Introduction
- Menu Bar
- Tool Bar
- System Tree Window
- Wizards
- Configuration Wizard
- Add Initiator Wizard
- FW Update Wizard
- Map Local Initiator/Target Wizard
- Unmap Local Initiator/Target Wizard
- Add Remote Router Wizard
- Remove Remote Router Wizard
- Map Remote Initiator/Target Wizard
- Unmap Remote Initiator/Target Wizard
- Discover iSCSI Target Wizard
- FCIP Route Add Wizard
- FCIP Route Remove Wizard
- A Command Reference
- Logging On to a SAN Router
- Guest Account
- Working with SAN Router Configurations
- Commands
- Admin Command
- Beacon Command
- Clear Command
- Date Command
- FcipRoute Command
- FRU Command
- Help Command
- History
- Image Command
- Initiator Command
- Localmap Command
- Logout Command
- Password Command
- Ping Command
- Quit Command
- Reboot Command
- Remote Map Command
- Remote Peer Command
- Reset Factory Command
- Save Command
- Set Command
- Set CHAP Command
- Set FC Command
- Set Features Command
- Set iSCSI Command
- Set iSNS Command
- Set Mgmt Command
- Set NTP Command
- Set Properties Command
- Set SNMP Command
- Set System Command
- Show Command
- Show CHAP Command
- Show FC Command
- Show FcipRoutes Command
- Show Features Command
- Show Initiators Command
- Show iSCSI Command
- Show iSNS Command
- Show Localmaps Command
- Show Logs Command
- Show Memory Command
- Show Mgmt Command
- Show NTP Command
- Show Performance Command
- Show Presented Initiators Command
- Show Presented Targets Command
- Show Properties Command
- Show Remotemaps Command
- Show Remotepeers Command
- Show SNMP Command
- Show Stats Command
- Show System Command
- Show Targets Command
- Show VLAN Command
- Shutdown Command
- Target Command
- Traceroute Command
- B Log Messages
- C Configuring CHAP
- D Simple Network Management Protocol (SNMP)
- Index

B – Log Messages
Fatal Log Messages
FI0054601-00 C B-25
A
System
The system modules generate the error log messages listed in Table B-12 and
described following the table.
Fatal Log Messages
The following sections list and describe the fatal log messages by reporting
module.
iSCSI Driver
The following fatal log messages are common to both iSCSI ports, 1 (GE1) and 2
(GE2). They are listed in Tabl e B- 13 and described following the table. Log
messages beginning with #0 denote iSCSI port 1 (GE1). Log messages beginning
with #1 denote iSCSI port 2 (GE2).
Table B-12. System—Error Log Messages
ID Log Message No.
237572 "Failed to kill sys killer %d\n" 4
237573 "Temperature over high threshold %d\n" 5
4 Failed to kill system task.
5 Reporting router exceeds maximum operating temperature.
Table B-13. iSCSI Driver—Fatal Log Messages
ID Log Message No.
69652 #%d: qlutm_init: Diagnostic failed, invalid SRAM 20
69653 #%d: qlutm_init: Diagnostic failed, fail reboot 21
69654 #%d: qlutm_init: Diagnostic failed, invalid NVRAM 22
69655 #%d: qlutm_init: Diagnostic failed, invalid DRAM 23
69656 #%d: qlutm_init: Failed to return diagnostic result to Bridge 24
69941 #%d: QLUtmProcessResponseQueue: Invalid handle %x
EntryType %x
309
69951 #%d: QLSetNvram: QLRebootTimer failed AF %x RS %x
Time %d
319