Installation guide

A – Specifications
Environmental
59096-06 A A-7
A
Environmental
Table A-7. Environmental Specifications
Temperature
Operating..................................
Non-operating...........................
0 to 40°C (32 to 104°F)
-40 to 70°C (-40 to 158°F)
Humidity
Operating..................................
Non-operating...........................
15% to 80%, non-condensing
5% to 90%, non-condensing
Altitude
Operating..................................
Non-operating...........................
0 to 3048 m (0 to 10,000 feet)
0 to 15,240 m (0 to 50,000 feet)
Vibration
Operating..................................
Non-operating...........................
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
Shock
Operating..................................
Non-operating...........................
IEC 68-2-7
4 g, 11ms, 20 repetitions
30g, 3 axis, 13 msec, trapezoidal pulse
Air flow........................................... Front-to-back or back-to-front