User`s manual
P
r
eli
mi
n
a
ry
Switch Faceplate Display (Port Display/TL Configuration)
SANbox-8/16 Switch Management
2-60 SANsurfer Switch Management 59010-06 Rev. A User’s Manual
device is recognized by the application but no attempt will be made to communi-
cate with it.
Communicating between Public Initiators to Private Targets
Public initiators should be connected to F_ports or Fabric ports. The targets
attached to the TL_ports will be automatically bridged by the switch to the initia-
tors registered with the name server.
Communicating between Private Initiators to Private Targets
The switch will bridge all targets to initiators registered with the name server. Each
TL_port which contains private initiators will require that each initiator be individ-
ually bridged to the desired devices listed on the Translation Entries list for that
port. A sample of bridging between private initiators and private targets is shown in
Figure 2-19.
Communicating between Private Initiators to Public Targets
Each TL_port which contains private initiators will require that each initiator be
individually bridged to the desired devices listed on the Translation Entries list for
that port. No action is required for the targets since they should be on fabric ports.