User`s manual

P
r
eli
mi
n
a
ry
Switch Faceplate Display
SANbox-8/16 Switch Management
Users Manual 59010-06 Rev. A SANsurfer Switch Management
2-47
FLS IO Transfer (IO/T) IO/T chassis provide Input-Output fabric ports
that connect to users and also Transfer ports that connect the switch to other
switches in a fabric.
FLS Cross-Connect (CC) A CC chassis provides interconnects between
IO/T chassis. A CC is not connected to any initiators or targets.
SL - Private Loop The Private Loop stage type forces all ports, not used as
T_Ports, to be SL_Ports configured in one SL_Port Zone. That is, all
SL_Ports share the same set of AL_PAs. Private Loop also allows these
SL_Port Switch chassis to be connected together in a Cascade topology. The
maximum number of SL_Ports in this one SL_Port Zone is 32. Make the
appropriate selection and press the Apply button to apply the new Stage Type
to the chassis.
Refer to the fabric descriptions in Section 5 (for multi-chassis fabrics) of the
applicable switch manual for information about the IO/T and CC stage types.
Make the appropriate selection and press the Apply button to apply the new
Stage Type to the chassis.
Admin Mode
The Administration Mode is the state of the chassis as determined by this screen.
Choose one of the following:
online The switch is available for normal operation.
offline The switch is not available.
self-test The switch is not available for normal operation and is being
tested by an external source.
Press the Apply button to apply the mode to the chassis.
R_T_TOV
The R_T_OV field controls the Receiver_Transmitter_Timeout value for all ports
on the chassis. Select the field, type the new value. The number is in ms (2000 = 2
seconds).
The default is 100 and should not be changed without consulting QLogic Customer
Support or your authorized service provider.
Press the Apply button to apply the new timeout value to the chassis.
E_D_TOV
The E_D_TOV field controls the Error_Detect_Timeout value for all ports on the
chassis. Select the box, type the new value. The number is in ms (2000 = 2
seconds).