B-6 Counter Descriptions 59010-06 Rev. A User’s Manual
Internal Parity ASIC 0 Port 1 Parity error detected with data transfer internal to the switch. A
non-zero value may indicate an internal probliem with the switch.
Internal Parity ASIC 0 Port 2
Internal Parity ASIC 0 Port 3
Internal Parity ASIC 0 Port 4
Internal Parity ASIC 1 Port 1
Internal Parity ASIC 1 Port 2
Internal Parity ASIC 1 Port 3
Internal Parity ASIC 1 Port 4
Internal Parity ASIC 2 Port 1*
Internal Parity ASIC 2 Port 2*
Internal Parity ASIC 2 Port 3*
Internal Parity ASIC 2 Port 4*
Internal Parity ASIC 3 Port 1*
Internal Parity ASIC 3 Port 2*
Internal Parity ASIC 3 Port 3*
Internal Parity ASIC 3 Port 4*
Intr low Bufs ASIC 0 Number of times a low buffer condition has occurred on the
specific ASIC.
Intr low Bufs ASIC 1
Intr low Bufs ASIC 2*
Intr low Bufs ASIC 3*
Out of buffers Number of large frames that have been sent by this switch.
Out of s-buffers Number of small frames that have been sent by this switch.
Switch resets Number of times the switch has been reset since it was
manufactured.
Table B-2 Counter Names and Descriptions (Faceplate window) (Continued)
Counter Description
* Only available for switches with more than 8 ports.