User`s manual
P
r
eli
mi
n
a
ry
show <command type>
SANbox-8/16 Switch Management
3-10 Telnet 59010-06 Rev. A User’s Manual
board_temp = actual measured temperature
Fan 1 status = operation of fan 1
Fan 2 status = operation of fan 2
Port Information = port type definition and fibre channel address
chassis_mode
The command returns a display similar to the following:
Active Admin Chassis Mode: :NOT USED
config
The command returns a display similar to the following:
SANbox 8
Chassis Num Locked :YES
Stage Type :I/O Transfer
Fabric ID :01
Admin Mode :online
MFS_TOV :0
R_T_TOV :100
E_D_TOV :2560
R_A_TOV :5000
Switch Resets :5000
Port Admin State AL Enabled MFS_MODE
1 Online True Normal
2 Online False Normal
3 Online True Normal
4 Online True Normal
5 Online True Normal
6 Online True Normal
7 Online True Normal
8 Online True Normal
Where:
Chassis Num Locked: YES = chassis number assigned manually
NO = chassis number assigned by fabric
Stage Type: I/O Transfer, Cross-Connect, or Hub Emulation
Fabric ID: fabric this switch is attached to
Admin Mode: online, offline, or self-test
MFS_TOV: MFS_Timeout value (in ms)
R_T_TOV: Receiver_Transmitter_Timeout value (in ms)
E_D_TOV: Error_Detect_Timeout value (in ms)
R_A_TOV: Resource_Allocation_Timeout value (in ms)
Switch Resets: number of switch resets since the switch was built
Ports: Admin State: Online, Offline,
AL Enabled: True, False
MFS_MODE: Normal,