User`s manual
Table Of Contents
- Preface
- General Description
- Installation
- Introduction
- Unpack
- Place or Mount the Equipment
- Apply the IEC Class 1 Laser Information Label (If the installation is in Europe)
- Install GBICs
- Connect to AC Power
- Switch Logic Power Good LED
- Check the Power-On-Self-Test (POST) Results
- Cable Fibre Channel Devices to the Switch
- Configure the Chassis
- Configure the Ports
- Zoning
- Rack and Shelf Administration
- Operating the Switch
- Diagnostics/Troubleshooting
- Removal/Replacement Procedures
- Multi-Chassis Fabrics
- Reference Information
- QLogic Customer Support
- Index

Preliminary
Multistage Topology
SANbox-16STD Fibre Channel Switch
5-14 Multi-Chassis Fabrics 59012-03 Rev. A Installer’s/User’s Manual
Figure 5-4 SANbox-16 Multistage with two T_Port links from each IO/T chassis
Figure 5-4 shows a Multistage Switch built from SANbox-16 chassis. Each of the
eight IO/T chassis has two T_Port connections to the CC chassis. This provides
200 MBytes of bandwidth between each IO/T chassis and failover in case a T_Port
fails. Each IO/T chassis distributes the available T_Port access among its user
ports. If a T_Port fails, the chassis distributes the user ports from the failed T_Port
to other T_Ports that are good.
There are 14 user ports remaining on each IO/T chassis. All user ports may be F,
FL, SL, or TL_Ports.
2
2
2
2
2
2
2
2