SANbox-16STD Fibre Channel Switch Specifications
SANbox-16STD Fibre Channel Switch
Installer’s/User’s Manual 59012-03 Rev. A Reference Information A-5
Operating Vibration: ..........................During/after (in any axis) of magnitude:
5-500 Hz, random,
0.21 G rms, 10 minutes
Operating Shock: ...............................During/after (in any axis) of magnitude:
4 g, 11 ms, 20 repetitions
Air flow: .............................................Model A: Cooling air flows from the front to
the back.
Model B: Cooling air flows from the back to
the front
Heat output:........................................600 BTU/hr fully populated
Non-Operational Temperature: ..........-40 to +70°C
Non-Operating Humidity:..................5 to 90%, non-condensing
Non-Operating Altitude: ....................0 to 15240m (0 to 50,000 feet)
Non Operating Vibration:...................(In any axis): 5-500 Hz, random,2.09 G rms,
10 minutes
Non Operating Shock:........................30 G 292 ips, 13 msec, 3 repetitions, 3 axis
Switch Regulatory Certifications
Safety Standards: ...............................UL1950
CSA 22.2 No. 950
EN60950
Emissions Standards: .........................FCC Part 15B Class A
VCCI Class A ITE
CISPR 22, Class A
EN 55022, Class A
Voltage Fluctuations: .........................EN 61000-3-3
Harmonics:.........................................EN 61000-3-2
Immunity:...........................................EN 50082-1:1997
Marking:.............................................FCC Part 15
UL (United States)
UL (Canada)
TUV
VCCI
CE
For more information refer to “Communications Statements” in the Preface.