User`s guide
-26 Sun StorEdge network FC switch-8 and switch-16 Operations Guide • August 2001
1. Launch the SANsurfer and connect to the switch.
See “To Replace a Switch in a Two-Switch Fabric” on page 14 and follow the steps
for launching and connecting.
2. Replace the switch.
See “To Replace a Switch in a Two-Switch Fabric” on page 14 and follow the steps
for replacing the switch.
3. Configure the replacement switch for the Network.
See “To Configure the Network for a Replacement Switch” on page 19.
▼ To Replace the Switches When Both Switches Have Had
Catastrophic Failures—No Saved Settings
The First Switch
1. Launch the SANsurfer and connect to the switch.
See “To Replace a Switch in a Two-Switch Fabric” on page 14 and follow the steps
for launching and connecting.
2. Save the settings.
See “To Save the Settings” on page 16.
3. Replace the switch.
See “To Replace a Switch in a Two-Switch Fabric” on page 14 and follow the steps
for replacing the switch.
4. Install the new switch.
See “To Install the New Switch” on page 21 .
The Second Switch
You must replace the second switch.
1. Launch the SANsurfer and connect to the switch.
See “To Replace a Switch in a Two-Switch Fabric” on page 14. Use the IP address of
the switch you just replaced.
Note – Pay close attention to the Chassis ID section.
2. Replace the switch.