User`s guide

Sun StorEdge Network FC Switch-8 and Switch -16 Switch Operations—Switch 3.0 -9
â–  The correctness of the switch logic, with the help of various read/write register
and loopback data-path tests.
0.5 Troubleshooting
Customer level troubleshooting instructions are provided in the Switch 3.0
Installation and Configuration Guide. Additional troubleshooting information, for
ES use only, is provided in the Sun StorEdge Network FC Switch-8 and Switch-16
Troubleshooting Guide, 816-1701-xx.
0.5.1 Capture
The line command capture gathers switch configuration data and writes it to
standard output.
0.5.1.1 Synopsis
capture [-nvram] Sw_IP_addr
0.5.1.2 Description
Capture provides a convenient way to retrieve all SANbox switch configuration
information and the current operational status, and print it in a readable form. The
information is written to standard output.
Capture is a useful way to document a configuration and the conditions when a
problem is reported, and its output should be included with all problem reports. If
it is specified, the parameter [-nvram] dumps the configuration in hex format. This
information is not useful unless the HeartBeat light indicates nvram corruption. If
nvram corruption is present, the HeartBeat light blinks 15 times, pauses, and then
repeats the error code.
The following data is recorded:
IP Address Configuration
Net IP Address: IP address of the switch
Net Mask: Network mask used by the switch