User`s guide

Sun StorEdge Network FC Switch-8 and Switch -16 Switch Operations—Switch 3.0 -7
5. Double-click the switch icon.
The Topology View screen is erased, and the Switch FacePlate Display screen
displays.
6. Make a note of the firware revision level.
The revision level appears on the second line of the text in the upper right corner of
the Switch FacePlate Display screen.
To Load the Flash
1. Locate the file containing the new flash code on the management station.
The default location is /usr/opt/SUNWsmgr/flash.
2. Choose Special>Update Flash.
The application displays a standard Open dialog box that allows you to browse to
and then open the Flash Update binary file. When you select the Flash Update file,
the switch checks the file for a valid checksum. Then, if the checksum is correct, the
Flash load begins.
If the checksum is not correct, the application warns you.
3. Make sure you select the correct flash code.
The flash file for the 8-port switch is m080304xx.fls.
The flash file for the 16-port switch is m160304xx.fls.
Select the filename with the highest xx number.
The application displays information about the progress of the flash update:
File: The name of the flash update binary file
Position: Number of bytes downloaded
Total: The total number of bytes in the file
Complete: The percentage of the file sent to the chassis
When the flash load is complete, the application displays a dialog box that states
that the flash load is complete and asks whether to Reset Immediately.
4. If you want to Reset, click Yes.
Remember that a Reset operation disrupts the operation of the switch.
5. If you do not want to Reset until traffic is removed from the switch, click No.
You can perform the Reset later by choosing Special>Reset in any of the Chassis
FacePlate windows.