-6 Sun StorEdge network FC switch-8 and switch-16 Operations Guide • August 2001
2. Enter the switch IP address in the Fabric window of the GUI.
It may take a few seconds for the switch icon to become gray. You can click the
Refresh button.
3. After the switch icon becomes gray, click the icon.
Note – If the icon remains red, it is likely that the IP address is wrong, or that the
switch cannot be accessed from that subnet, or the switch lacks power or an ethernet
connection.
▼ To Verify the Flash
You must have the correct flash for the 3.0 version of the GUI in each switch of the
fabric. For cascaded switches, both switches must have the same flash version.
▼ To Verify the Firmware Revision Level of the switch(es):
Perform the following procedure for each switch.
1. Verify that the switches are not connected to each other.
2. Connect one switch to the net.
3. Launch the GUI and bring up the switch.
See “To Start the GUI Software” on page 5.
4. Open the Topology View screen.
The switch icon representing the connected switch displays in the right window
pane.