User`s guide
5 – QLA2344
FCode
5-6 FC2354601-00 E
Q
5.3.2
Setting the QLA2344 HBA Connection Mode
Perform the following steps to view the current QLA2344 HBA connection mode
and change it if necessary.
1. Select the QLA2344 HBA attached to the Fibre Channel device from which you
want to boot. For example, type the following at the ok prompt:
ok " /pci@1f,0/pci@1/QLGC,qla@4" select-dev
2. To view the current connection mode, type the show-connection-mode
command:
ok show-connection-mode
The connection mode and options display. For example:
Current HBA connection mode: 2 - Loop preferred, otherwise
point-to-point
Possible connection mode choices:
0 - Loop Only
1 - Point-to-point only
2 - Loop preferred, otherwise point-to-point
3. If the connection mode is not correct based on the devices connected to the
QLA2344 HBA, change it using the set-connection-mode command. For
example:
ok 0 set-connection-mode
The new connection mode displays. For example:
Calculating NVRAM checksum, please wait...
Current HBA connection mode: 0 - Loop Only
Possible connection mode choices:
0 - Loop Only
1 - Point-to-point only
2 - Loop preferred, otherwise point-to-point