Product specifications
1–Overview of the Release
Other Information
D000069-024 1-15
Older QLogic InfiniPath 2.2.1 and prior releases will not be recognized in the
installation menus and will be treated as if no InfiniBand software is installed.
When upgrading from an older QLogic OFED+ release to a new QLogic
OFED+, the older QLogic OFED+ release will be uninstalled first.
When installing the OFED Debug Info component, make sure that
~/.rpmmacros does not have any lines changing the %debug_package
macro.
If %debug_package is set to %{nil}, debuginfo RPMs will not be available
for installation.
The current setting for this parameter can be verified using:
rpm --eval '%{debug_package}'
If a non-blank output occurs, then debuginfo is enabled. If a blank line is
output, then debuginfo is disabled on the present system.
When running QLogic SRP over two ports in round robin mode, performance
is degraded.
When running verbs-based benchmarks such as ib_send_bw, the following
message may appear:
BUG: soft lockup - CPU#1 stuck for 10s.
This message does not impact completion or correctness of the benchmark.
The ib_send_bw benchmark, when run in UC mode, is written such that it
will hang if even one packet is dropped.
The QLogic 12000 series switch firmware must be at version 6.0.0.1.2 or
later to connect with the TrueScale Host Channel Adapters in this release.
QLE7240/QLE7280 performance with Barcelona stepping B2 and the
BIOS/kernel workaround for AMD errata 298 can lead to reduced InfiniBand
bandwidth, as a result of poor memory bandwidth and latency on the
adapters due to the workaround. To fix this problem, upgrade to Barcelona
stepping B3 (or later).