User`s guide

3 – Event Messages
Alarm Events
3-10 59060-00 03
0
[A] [1005.0024] [Switch must be reset after leaving the Diagnostics Admin State]
Meaning: After changing the switch administrative state from Diagnostics to
any other state, the switch must be reset to complete the state
change.
Action: Reset the switch.
[A] [1005.0039] [Fabric Login (FLOGI) from address FC_address failed]
Meaning: The payload of the FLOGI was not valid.
Action: Check device connection or replace the device. If the problem
persists, contact your authorized maintenance provider.
[A] [1005.003B] [Warning - Debug logging filter level is set]
Meaning: Debug logging has been set using the Set Log Level command.
Action: Confirm that you intended to do this. If not, use the Set Log Level
command to change the severity level to Info, Warn, or Critical.
[A] [1006.0004] [Zoning conflict, device_WWN is in an Access Control List (ACL) hard
zone, but device_WWN share a soft zone]
Meaning: The named zone members cannot communicate because they are
members of different ACL hard zones.
Action: Place both zone members in the same ACL hard zone or exclude
both from ACL hard zones.
[A] [1006.0005] [Zoning enforcement error in Nameserver]
Meaning: An error occurred while checking ACL zoning.
Action: Contact your authorized maintenance provider.
[A] [1006.0006] [Zoning conflict, device_WWN and device_WWN do not share an Access
Control List (ACL) hard zone, but device_WWN share a soft zone]
Meaning: The named zone members cannot communicate because they are
members of different ACL hard zones.
Action: Place both zone members in the same ACL hard zone or exclude
both from ACL hard zones.