User`s guide
3 – Event Messages
Alarm Events
59060-00 03 3-9
0
[A] [1004.0035] [Failed to connect to a switch due to incompatibility - check interop
settings.]
Meaning: The remote switch is incompatible.
Action: Inspect the interoperability settings on the remote switch.
[A] [1004.0036] [Domain ID domain_ID assigned to different switches. Cannot join fabrics.]
Meaning: An attempt was made to join two fabrics that possessed switches
with the same domain_ID.
Action: Change the domain_ID on one of the switches so that it is unique,
and join the fabrics again.
[A] [1005.000A] [Cannot enforce zoning for member domain_ID, port_number, this zone
member will be ignored]
Meaning: A zone member given by domain ID and port number could not be
found in the fabric.
Action: Examine the fabric connections and zoning definitions.
[A] [1005.000C] [Configuration error, insufficient credit in pool. Extended credit not
granted for port port_number]
Meaning: Insufficient credits were available in the credit pool to grant the
credit request.
Action: Decrease the number of requested credits or add more donor
ports.
[A] [1005.000D] [Configuration error, insufficient credit in pool. Extended credit not
granted for port port_number]
Meaning: Insufficient credits were available in the credit pool to grant the
credit request.
Action: Decrease the number of requested credits or add more donor
ports.
[A] [1005.000E] [Configuration error, can't extend credit on loop capable ports. Extended
credit not granted for port: port_number]
Meaning: Loop ports cannot borrow credits from the credit pool.
Action: Change the port type to G_Port or F_Port.
[A] [1005.0020] [Warning - development logging is enabled]
Meaning:
Action: