3 – Event Messages
Alarm Events
3-8 59060-00 03
0
[A] [1004.0029] [No Switch capable of being Principal Switch. Reconfigure Principal
Switch Priority.]
Meaning: An E_Port isolated because the principal priority on all switches is
set to 254.
Action: Configure one of the switches to be the principal switch by
changing the principal priority.
[A] [1004.002B] [Port port_number not configured for E-Port capability, reconfigure to G/GL
to connect to remote switch]
Meaning: An attempt was made by a remote switch to connect through a port
that could not configure itself as an E_Port.
Action: Change the port type on the remote switch to G_Port or GL_Port.
[A] [1004.002D] [Non-interop Legacy switch setting prevents domain/port zoning]
Meaning: Zone members involving non-QLogic switches cannot be defined
by domain ID and port number when Interop Mode is disabled and
Legacy Address Formatting is enabled.
Action: Disable (False) the Legacy Address Formatting, enable Interop
Mode, or reassign the zone members using a method other than
domain ID and port number.
[A] [1004.0030] [Topology change, lost route to switch with domain ID domain_ID]
Meaning: Connection was lost to a switch in the fabric.
Action: Inspect switch connections and device hardware for proper
operation. Review accompanying alarms for other causes.
[A] [1004.0032] [E_Port not supported on remote port. Reconfigure remote switch to
connect.]
Meaning: An E_Port isolated because the port on the remote switch could
not configure itself as an E_Port.
Action: Change the port type on the remote switch to G_Port or GL_Port.
[A] [1004.0033] [Remote switch is in Interop mode or using Legacy Address Format]
Meaning: A remote switch is attempting to connect with conflicting settings
for Interop mode or legacy address format.
Action: Configure the switches so that Interop mode and Legacy Address
Format settings are the same throughout the fabric.
[A] [1004.0034] [Failed to connect to a switch due to incompatibility - contact technical
support.]
Meaning: The two switches are incompatible.
Action: Contact your authorized maintenance provider.