Installation guide
59055-00 B 5-1
Section 5
Diagnostics/Troubleshooting
Diagnostic information about the switch is available through the chassis LEDs and
the port LEDs. Diagnostic information is also available through the SANbox
Manager and CLI event logs and error displays. This section describes two types
of diagnostics: Power-On Self Test (POST) and chassis. POST diagnostics
describe the Heartbeat LED and the port Logged-In LED indications. Chassis
diagnostics cover power supply and fan diagnostics as well as over temperature
conditions. This section also describes how to use maintenance mode to recover
a disabled switch.
5.1
POST Diagnostics
The switch performs a series of tests as part of its power-up procedure. The
POST diagnostic program performs the following tests:
Checksum tests on the boot firmware in PROM and the switch firmware in
flash memory
Internal data loopback test on all ports
Access and integrity test on the ASIC
During the POST, the switch logs any errors encountered. Some POST errors are
critical, others are not. The switch uses the Heartbeat LED and the Logged-In
LED to indicate switch and port status. A critical error disables the switch so that it
will not operate. A non-critical error allows the switch to operate, but disables the
ports that have errors. Whether the problem is critical or not, contact your
authorized maintenance provider.
If there are no errors, the Heartbeat LED blinks at a steady rate of once per
second. If a critical error occurs, the Heartbeat LED will show an error blink
pattern and the System Fault LED will illuminate. If there are non-critical errors,
the switch disables the failed ports and flashes the associated Logged-In LEDs.
Refer to ”Heartbeat LED Blink Patterns” on page 5-2 for more information about
Heartbeat LED blink patterns.