Product specifications

Switch Command Line Interface
Groups and Commands
1-80 D000103-000 E
smDbSyncInterval
Displays how often a Master subnet manager should perform a full synchronization with the standby
subnet manager(s).
Syntax:
Options:
Sample Output:
NOTES: Value must be between 0 and 60 minutes (0=OFF). The subnet manager
must be running to display this information.
smDbSyncInterval
None.
-> smDbSyncInterval
SM DB full sync interval currently set to 15 minutes
-----SM DB SYNCHRONIZATION interval set to 900 seconds, 2 SM(s) in fabric-----
MASTER SM node at QLogic 12300 GUID=0x00066a00d90003fa, LID 0x0008, PortGuid
0x00066a00d90003fa
Sync Capability is SUPPORTED
STANDBY SM node at st44, LID 0x0100, PortGuid 0x00066a00a0000357
Sync Capability is SUPPORTED
Full sync status is SYNCHRONIZED
Time of last Full sync is THU APR 10 15:37:47 2008
Time of last INFORM records sync is THU APR 10 15:37:47 2008
Time of last GROUP records sync is THU APR 10 15:37:47 2008
Time of last SERVICE records sync is THU APR 10 15:37:47 2008