Installation guide

1–Installation
Bringing Up the System For the First Time
1-52 D000140-001 D
Changing the Switch IP Address and Default Gateway via the
CLI
The command line interface (CLI) can be accessed via Telnet, SSH, the SEEB
module DB-9 or 12200/12300 RS-232 serial port(s).
1. Determine the CLI access method (that is, Telnet, SSH, or Serial).
2. Connect appicable serial cables to the RS-232/DB-9 ports of the switch.
Connect the other end to a workstation. If using a terminal emulation device,
the settings should be:
8 data bits
no parity bits
1 stop bit
57.6K baud
Use VT100 emulation.
Flow control = XON/XOFF
3. If using Telnet or SSH, access the switch with the following command:
open 192.168.100.9
4. The system prompts for a user name. In order to change the IP address and
default gateway, the user must be logged in as the administrator. At the
prompt enter:
admin
5. The system prompts for a password. At the prompt enter:
adminpass
The system responds with:
NOTE:
If using a serial port, skip to Step 6. Steps 2 through 5 are for those users
accessing the switch via Telnet or SSH. For the 12800 series, make certain
to connect to the SEEB serial port associated witht the Master Management
Module (MM). These are:
12800-040: MM 201
12800-120: MM 207
12800-180: MM 211
12800-360: MM 227