Installation guide
D000140-001 D D-1
D FRU Replacement
This section details replacement information for various QLogic 12000 field
replaceable units (FRUs). For replacement parts, contact QLogic or an approved
reseller.
QLogic 12200
Chassis Replacement
FRU part number:
Standard chassis: 12200-BS01
Reversed airflow/AC power inlets: 12200-BS02
Removal Procedures
1. Power down the switch by unplugging AC power.
2. Remove all applicable IB, Ethernet and Serial cables. Set these aside for
reinstalling the replacement switch.
NOTE:
If it is part of a standard operating procedure, add replacement identification
tags to both the rack and the FRU hardware to ensure that the warranty is
transferred to the replacement part(s).
NOTE:
If the FRU being replaced is in an active chassis (that is, hot swapping),
please replace the FRU within 2 minutes to maintain thermal integrity.
NOTE:
For an externally-managed 12200, refer to the Fast Fabric User Guide for
update information.