Installation guide
1–Installation
12800-180 Installation
1-14 D000102-000 B
12800-180 Installation
NOTE:
The following procedures are for installing the switch using a fixed distance
between the front and rear rack posts.
Mounting Hardware Kit Contents:
NOTE:
The mounting kit contains all of the necessary parts for installing and
mounting the switch into a 19" 4-post server rack with a distance between
front and back posts of 719mm and 742mm.
• Support Rails
•Flat Brackets
• U-Brackets
• #8-32 Flat Head Screws
• #10-32 Flat Head Screws
• M6 Mounting Screws
• M6 Clip Nuts
Installation Tasks
1. If applicable, remove the doors of the rack. Mark the rack and install M6 clip nuts.
NOTE:
It is recommended that 12800-180 is installed into the rack at 5U or 6U
location. This locates the chassis approximately 12" from the floor and
allows the chassis to be moved onto the support rails by sliding off of the
pallet.