Installation guide
Configuring a CLARiiON boot device
95
Configuring a Boot Device on an EMC Storage Array
◆ SCSI hard disks are allowed in SAN boot configurations.
However, the BIOS for the disk's SCSI adapters must be disabled.
Any SCSI disks attached to the host should be disconnected
during the operating system installation.
◆ For servers with SCSI CD-ROM drives, ensure that the BIOS is
enabled on the SCSI channel that includes the CD-ROM. Disable
the BIOS on any other integrated SCSI channels.
◆ For servers with IDE CD-ROM drivers, disable the BIOS on the
server's integrated SCSI adapter(s). The SCSI BIOS is not required
to boot from the CD-ROM.
◆ Disable the BIOS on any other adapters in the system other than
the QLogic adapter designated for booting.
Configuring the QLogic BIOS for SAN boot
After the BIOS is installed and enabled, it must be configured for use
for booting from the SAN. The following procedure describes how to
configure the BIOS.
1. Connect the CLARiiON SP Fibre Channel port to the adapter in
the lowest-numbered PCI slot in the server.
2. Boot the server, and press CTRL-Q when the QLogic banner is
displayed.
Note: Different adapter models may display different banners. Be sure to
press CTRL-Q for the adapter to be configured.
The banner display corresponds to the BIOS revision pertinent to
the adapters currently installed. Refer to the EMC Support Matrix
for specific adapters and BIOS revisions.
3. After Fast!UTIL loads, the display depends on whether there are
multiple QLogic adapters installed:
• If there is only one QLogic adapter, the Fast!UTIL Options
menu appears.